必威体育登录手机The exceptional inertness of Agilent J&W DB-5ms Ultra Inert GC columns delivered superior results for basic compounds in a comparison of -5ms phases.
- Publication Part Number: 5991-4626EN
- Created: 13 May 2014
- 224 KB
Publication Part Number | 5991-4626EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Effective analysis of multiple pesticides in water used an Agilent 5975T LTM GC/MSD with stir bar sorptive extraction and a Thermal Separation Probe.
- Publication Part Number: 5991-4264EN
- Created: 14 Mar 2014
- 230 KB
Publication Part Number | 5991-4264EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent Bond Elut QuEChERS kits provided adequate cleanup, recovery, and reproducibility of 176 pesticides in highly pigmented tea samples.
- Publication Part Number: 5991-3728EN
- Created: 09 Dec 2013
- 190 KB
Publication Part Number | 5991-3728EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Several solvents and analyte protectants were evaluated for their ability to stabilize and maximize the recoveries of a number of organophosphorous pesticide residues.
- Publication Part Number: 5991-1808EN
- Created: 25 Oct 2013
- 1 MB
Publication Part Number | 5991-1808EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Method development for QuEChERS sample preparation is used to extract pesticide residues in highly variable concentrated fruit juices, followed by GC/MS/MS
- Publication Part Number: 5991-3342EN
- Created: 21 Oct 2013
- 6 MB
Publication Part Number | 5991-3342EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机The Agilent Inert Flow Path outperformed a non-Agilent version for trace pesticides, with less impact on analytes and better results for some critical pesticides.
- Publication Part Number: 5991-3234EN
- Created: 19 Sep 2013
- 925 KB
Publication Part Number | 5991-3234EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机An Agilent 7890B GC system configured with three detectors was used for the analysis of pesticides in water.
- Publication Part Number: 5991-2787EN
- Created: 05 Aug 2013
- 1 MB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
This note describes an analytical method for the determination of pesticide residues in fruits using a modified QuEChERS method for extraction and analysis by LC-QTOF MS.
- Publication Part Number: 5991-1872EN
- Created: 07 Feb 2013
- 799 KB
Publication Part Number | 5991-1872EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Portuguese (Brazil) | Complete (PDF) |
---|
必威体育登录手机Agilent Ultra Inert liners with wool give accurate and precise pesticide trace levels from 5 µL extracts in acetonitrile.
- Publication Part Number: 5991-1196EN
- Created: 04 Oct 2012
- 1 MB
Publication Part Number | 5991-1196EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for Organophosphorus Pesticides in Apple Matrix by GC/MS/FPD using an Agilent J&W DB-35ms Ultra Inert GC Column
- Publication Part Number: 5990-7165EN
- Created: 06 Jan 2012
- 841 KB
Publication Part Number | 5990-7165EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (United States) | Complete (PDF) |
必威体育登录手机Application note for a Blind Study of Pesticides in Vegetables by Bond Elut QuEChERS Extraction Kits and Agilent 5975T LTM GC/MSD
- Publication Part Number: 5990-6323EN
- Created: 06 Jan 2012
- 121 KB
Publication Part Number | 5990-6323EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (United States) | Complete (PDF) |
Application note for the determination of pesticides in lemon oil via modified QuEChERS method
- Publication Part Number: 5990-6432EN
- Created: 06 Jan 2012
- 1 MB
Publication Part Number | 5990-6432EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
Describing the use of the AOAC buffered extraction method followed by the use of the Universal Dispersive SPE method for preparing lettuce and apple samples for GC/MS.
- Publication Part Number: 5990-6558EN
- Created: 06 Jan 2012
- 961 KB
Publication Part Number | 5990-6558EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates nine organophosphate pesticides in 15 minutes.
- Publication Part Number: A0358
- Created: 31 Oct 2011
- 695 KB
Publication Part Number | A00358 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- Publication Part Number: A01617
- Created: 31 Oct 2011
- 489 KB
Publication Part Number | A01617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 19 pesticides and herbicides according to EPA 507 in 28 minutes.
- Publication Part Number: A1002
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A01002 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 14 organophosphorus pesticides in 27 minutes.
- Publication Part Number: A01108
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01108 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 19 pesticides and herbicides according to EPA 507 in 23 minutes.
- Publication Part Number: A00779
- Created: 31 Oct 2011
- 638 KB
Publication Part Number | A00779 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 25 organophosphorus pesticides according to EPA 8140 and 8141 in 31 minutes.
- Publication Part Number: A0615
- Created: 31 Oct 2011
- 867 KB
Publication Part Number | A00615 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separate 58 organophosphorus pesticides in 26 minutes.
- Publication Part Number: A01348
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A01348 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|