Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
note cites and is supported by a VOC kit that contains the necessary parts to implement this VOC solution set.
- Publication Part Number: 5991-0029EN
- Created: 23 June 2015
- 4 MB
Publication Part Number | 5991-0029EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Analyzing landfill site odors and toxic volatile compounds using a time dependent process.
- Publication Part Number: 5991-2825EN
- Created: 26 July 2013
- 3 MB
Publication Part Number | 5991-2825EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|
In China, since 2001, civil building engineering has been regulated by GB50325.
- Publication Part Number: 5991-1536EN
- Created: 05 Mar 2013
- 1 MB
Publication Part Number | 5991-1536EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Russian (Russia) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of coffee extract aroma in 50 minutes.
- Publication Part Number: A0850
- Created: 31 Oct 2011
- 525 KB
Publication Part Number | A00850 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column produces a fingerprint of apple juice aroma in 30 minutes.
- Publication Part Number: A0851
- Created: 31 Oct 2011
- 818 KB
Publication Part Number | A00851 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax FFAP 58 CB column produces a fingerprint of tomato juice aroma in 25 minutes.
- Publication Part Number: A0852
- Created: 31 Oct 2011
- 734 KB
Publication Part Number | A00852 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of shrimp aroma in 25 minutes.
- Publication Part Number: A0853
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A00853 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC using an Agilent J&W CP-Sil 5 CB column isolates methyl isothiocyanate, an indicator of the soil fumigant Monam, in water from a sewage treatment plant in eight minutes.
- Publication Part Number: A0298
- Created: 31 Oct 2011
- 270 KB
Publication Part Number | A00298 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates eight C1 to C2 halogenated hydrocarbons in water in 12.5 minutes.
- Publication Part Number: A1019
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01019 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 13 sulfur compounds in a wine in 33 minutes.
- Publication Part Number: A0444
- Created: 31 Oct 2011
- 602 KB
Publication Part Number | A00444 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine components in a sample of medium-heat milk powder with an oxidation flavor.
- Publication Part Number: A0846
- Created: 31 Oct 2011
- 472 KB
Publication Part Number | A00846 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates residual solvents in yoghurt in 16 minutes.
- Publication Part Number: A1046
- Created: 31 Oct 2011
- 657 KB
Publication Part Number | A01046 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 19 components in Darjeeling tea in 40 minutes.
- Publication Part Number: A1030
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A01030 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates six volatile aromatic hydrocarbons at low concentrations in water in 13 minutes.
- Publication Part Number: A0219
- Created: 31 Oct 2011
- 469 KB
Publication Part Number | A00219 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column identifies 12 aromas in a lily plant in 40 minutes.
- Publication Part Number: A1010
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A01010 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column isolates perchloroethylene from a food sample in 20 minutes.
- Publication Part Number: A0366
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00366 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces fingerprints of dried sardine samples in 30 minutes.
- Publication Part Number: A1028
- Created: 31 Oct 2011
- 726 KB
Publication Part Number | A01028 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine components from a one-year-old Gouda cheese.
- Publication Part Number: A0847
- Created: 31 Oct 2011
- 709 KB
Publication Part Number | A00847 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a deodorant fingerprint in 40 minutes.
- Publication Part Number: A1036
- Created: 31 Oct 2011
- 580 KB
Publication Part Number | A01036 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C6 to C13 aromatic hydrocarbons in 30 minutes.
- Publication Part Number: A0252
- Created: 31 Oct 2011
- 498 KB
Publication Part Number | A00252 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|