Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
- Compounds
-
- Detection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Advanced information gained using multi-detector GPC is highlighted in the investigation of branching in star polymers using the 1260 Infinity Multi-GPC/SEC System.
- Publication Part Number: 5991-2887EN
- Created: 01 May 2016
- 834 KB
Publication Part Number | 5991-2887EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
For a given particle size, the slope of the calibration curve in the molecular weight region of interest controls selectivity in GPC/SEC.
- Publication Part Number: 5990-8424EN
- Created: 30 Apr 2015
- 412 KB
Publication Part Number | 5990-8424EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for polystyrene stars on Agilent PLgel 5 μm MIXED-C using Gel Permeation Chromatography
- Publication Part Number: 5990-8487EN
- Created: 30 Apr 2015
- 639 KB
Publication Part Number | 5990-8487EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机PLgel columns and the Agilent ELSD provide a good combination for the separation of polymer additives
- Publication Part Number: 5990-8404EN
- Created: 14 June 2014
- 1 MB
Publication Part Number | 5990-8404EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This application note demonstrates how hydroxyethyl cellulose can be analyzed using Agilent PLgel and PL aquagel-OH GPC/SEC columns.
- Publication Part Number: 5991-4299EN
- Created: 17 Mar 2014
- 241 KB
Publication Part Number | 5991-4299EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
- Publication Part Number: 5990-8424JAJP
- Created: 07 Dec 2011
- 166 KB
Publication Part Number | 5990-8424EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
- Publication Part Number: 5990-8424CHCN
- Created: 01 July 2011
- 477 KB
Publication Part Number | 5990-8424EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|