Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
- Compounds
-
Compounds
- Detection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Agilent's new deactivation of the 6% cyanopropyl dimethylpolysiloxane (624) phase significantly improves acid performance and maintains very good performance.
- Publication Part Number: 5991-0845EN
- Created: 31 July 2012
- 2 MB
Publication Part Number | 5991-0845EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (United States) | Complete (PDF) |
---|
PH
- Publication Part Number: SI-02254
- Created: 05 Dec 2011
- 235 KB
Publication Part Number | SI-02254 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机GC analysis of 14 USP 467 solvents on an Agilent J&W VF-200ms column takes 15 minutes.
- Publication Part Number: A02204
- Created: 31 Oct 2011
- 540 KB
Publication Part Number | A02204 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Graphical analysis ot residual solvents of USP 467.
- Publication Part Number: SI-00944
- Created: 08 Oct 2010
- 216 KB
Publication Part Number | SI-00944 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机For USP-467 with Agilent J&W VF-624ms, replacing a 30 m x 0.32 mm column for one of 15 m x 0.15 mm reduces analysis time by more than half.because the efficiency is higher.
- Publication Part Number: A02430
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02430 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W VF-624ms column separates 27 residual solvents in 40 minutes.
- Publication Part Number: A02400
- Created: 11 May 2010
- 807 KB
Publication Part Number | A02400 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|