Application note for the identification and quantification of the Main Off-Flavors in Wine by GC/MS
- Publication Part Number: SI-01436
- Created: 16 Dec 2015
- 481 KB
Publication Part Number | SI-01436 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of black sesame in 50 minutes.
- Publication Part Number: A1033
- Created: 31 Oct 2011
- 641 KB
Publication Part Number | A01033 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of parged sesame in 50 minutes.
- Publication Part Number: A1034
- Created: 31 Oct 2011
- 501 KB
Publication Part Number | A01034 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of a hop plant in 50 minutes.
- Publication Part Number: A1009
- Created: 31 Oct 2011
- 918 KB
Publication Part Number | A01009 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of Bulgarian rose oil in 40 minutes.
- Publication Part Number: A1039
- Created: 31 Oct 2011
- 745 KB
Publication Part Number | A01039 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 23 C10 to C18 fatty acid methyl esters in ox fat in 28 minutes.
- Publication Part Number: A0474
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A00474 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 13 C6 to C20 fatty acid methyl esters in coconut oil in 42 minutes.
- Publication Part Number: A0476
- Created: 31 Oct 2011
- 722 KB
Publication Part Number | A00476 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates nine alcohols, acetates, aldehydes and dioxane in a whisky in 12 minutes.
- Publication Part Number: A0368
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00368 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of coffee powder aroma in 25 minutes.
- Publication Part Number: A0849
- Created: 31 Oct 2011
- 797 KB
Publication Part Number | A00849 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight alcohols in red wine in 16 minutes.
- Publication Part Number: A0706
- Created: 31 Oct 2011
- 521 KB
Publication Part Number | A00706 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a bread fingerprint in 40 minutes.
- Publication Part Number: A1027
- Created: 31 Oct 2011
- 695 KB
Publication Part Number | A01027 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 33 C10 to C22 fatty acid methyl esters in Russian fish oil in 54 minutes.
- Publication Part Number: A0475
- Created: 31 Oct 2011
- 660 KB
Publication Part Number | A00475 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates six C1 to C5 alcohols in a yeast (Saccharomyces) culture in 25 minutes.
- Publication Part Number: A0355
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A00355 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of shrimp aroma in 25 minutes.
- Publication Part Number: A0853
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A00853 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of Japanese bean paste, miso, in 45 minutes.
- Publication Part Number: A1032
- Created: 31 Oct 2011
- 574 KB
Publication Part Number | A01032 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of coffee extract aroma in 50 minutes.
- Publication Part Number: A0850
- Created: 31 Oct 2011
- 525 KB
Publication Part Number | A00850 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces fingerprints of dried sardine samples in 30 minutes.
- Publication Part Number: A1028
- Created: 31 Oct 2011
- 726 KB
Publication Part Number | A01028 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 27 aromas in a wine sample in 14 minutes.
- Publication Part Number: A01461
- Created: 31 Oct 2011
- 810 KB
Publication Part Number | A01461 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of tea aroma in 45 minutes.
- Publication Part Number: A0848
- Created: 31 Oct 2011
- 721 KB
Publication Part Number | A00848 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 10 components in two Pilsener beers in 27 minutes.
- Publication Part Number: A1026
- Created: 31 Oct 2011
- 544 KB
Publication Part Number | A01026 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|