Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Instrument
-
必威体育登录手机Agilent 6410 Triple Quadrupole Mass spectrometer (7)
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
An online SPE LCMS method has been developed for the rapid and robust analysis of trace organic compounds in water, eliminating the need for tedious extractions.
- Publication Part Number: 5991-2731EN
- Created: 08 Oct 2013
- 1 MB
Publication Part Number | 5991-2731EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Easy-to-use Agilent QuEChERS sample prep for fish is used for the analysis of nicotine and its metabolites with hydrophilic interaction chromatography (HILIC).
- Publication Part Number: 5991-2408EN
- Created: 03 May 2013
- 137 KB
Publication Part Number | 5991-2408EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Quantification of trace-level herbicides in drinking water by online enrichment with the Agilent 1200 Infinity Series Online-SPE Solution and Triple Quadrupole MS Detection.
- Publication Part Number: 5991-1738EN
- Created: 01 Apr 2013
- 2 MB
Publication Part Number | 5991-1738EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Ten N-methyl carbamates in juice were resolved in 7 minutes, < 1 ppb, using Agilent 6460 Triple Quad LC/MS and Poroshell 120 Bonus-RP LC.
- Publication Part Number: 5991-2124EN
- Created: 19 Mar 2013
- 541 KB
Publication Part Number | 5991-2124EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
An online SPE method has been developed for the rapid, sensitive, reproducible, and robust analysis of trace organic compounds in water
- Publication Part Number: 5991-1849EN
- Created: 05 Feb 2013
- 506 KB
Publication Part Number | 5991-1849EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
This application note describes the development of a triggered MRM database and library for more than 300 pesticides.
- Publication Part Number: 5991-1183EN
- Created: 16 Nov 2012
- 1 MB
Publication Part Number | 5991-1183EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
An online solid phase extraction (SPE) method for analyzing 17 chlorinated phenoxy acid herbicides and pentachlorophenol has been developed on a 6410 Triple Quadrupole LC/MS.
- Publication Part Number: 5991-0871EN
- Created: 02 Aug 2012
- 1 MB
Publication Part Number | 5991-0871EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A validated method for pesticide residue analysis in apples uses Agilent Chem Elut cartridges and a Poroshell 120 LC column.
- Publication Part Number: 5991-0868EN
- Created: 27 July 2012
- 2 MB
Publication Part Number | 5991-0868EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of pesticide residues in spinach using Agilent Bond Elut QuEChERS EN Kit by LC/MS/MS Detection
- Publication Part Number: 5990-4395EN
- Created: 06 Jan 2012
- 391 KB
Publication Part Number | 5990-4395EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of pesticide residues in apples using Agilent Bond Elut QuEChERS AOAC Kit by LC/MS/MS Detection
- Publication Part Number: 5990-3937EN
- Created: 06 Jan 2012
- 683 KB
Publication Part Number | 5990-3937EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Application Note describes the use of QuEChERS EN sample Prepation approach.
- Publication Part Number: 5990-6400EN
- Created: 06 Jan 2012
- 696 KB
Publication Part Number | 5990-6400EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of Pesticide Residues in Spinach Using Agilent Bond Elut QuEChERS AOAC Kit by LC/MS/MS Detection
- Publication Part Number: 5990-4248EN
- Created: 06 Jan 2012
- 280 KB
Publication Part Number | 5990-4248EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS European Standard EN Kits by LC/MS/MS Detection
- Publication Part Number: 5990-3938EN
- Created: 06 Jan 2012
- 682 KB
Publication Part Number | 5990-3938EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Application note for fast LC/MS/MS analysis of Group 4 Pharmaceuticals from EPA-1694 with RRHD HILIC Plus
- Publication Part Number: 5990-8433EN
- Created: 28 June 2011
- 77 KB
Publication Part Number | 5990-8433EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
The ADAC QuEChERS has been widely employed in the analysis of pesticides in food [1-2]...
- Publication Part Number: 5990-8034EN
- Created: 11 May 2011
- 928 KB
Publication Part Number | 5990-8034EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机The Agilent 6530 Quadrupole Time of Flight LCMS system with Jet stream ESI ion source coupled with Agilent 1290 Infinity UHPLC and Dispersive C18 ODS sample clean up
- Publication Part Number: 5990-7185EN
- Created: 28 Apr 2011
- 3 MB
Publication Part Number | 5990-7185EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机The recent advances and developments in HPLC and UHPLC systems, like the Agilent 1290 Infinity LC system...
- Publication Part Number: 5990-7776EN
- Created: 21 Apr 2011
- 1 MB
Publication Part Number | 5990-7776EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for the analysis of environmental samples with Ultra High Definition LC/Q-TOF MS and Accurate Mass
- Publication Part Number: 5990-6430EN
- Created: 23 Nov 2010
- 806 KB
Publication Part Number | 5990-6430EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
開發了一種可靠的檢測水庫原水中微囊藻毒素的LC/MS方法,檢出限低於0.005 ug/l
- Publication Part Number: 5991-2057CHCN
- Created: 02 Sep 2013
- 534 KB
Publication Part Number | 5991-2057EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机使用Agilent 6460 三重四極杆液質聯用係統對自來水中的高氯酸鹽進行高靈敏度的高效液相色譜分析
- Publication Part Number: 5991-1387CHCN
- Created: 08 Nov 2012
- 409 KB
Publication Part Number | 5991-1387EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|