Refine Results
- 必威体育赛事投注
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机The environment of the reactor in a nuclear power plant cnn be checked for the presence of gases with portable Agilent 490 Micro GC with Agilent J&W CP-Molsieve 5Å.
- Publication Part Number: A01621
- Created: 12 Aug 2022
- 241 KB
Publication Part Number | A01621 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column and Agilent 490 Micro GC separates ethylene chloride and water impurities in vinyl chloride in 90 seconds.
- Publication Part Number: A02213
- Created: 29 Apr 2015
- 115 KB
Publication Part Number | A02213 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机This application note describes the use of an Agilent Micro GC for gas composition analysis during fuel cell research and development and beta testing.
- Publication Part Number: 5991-3364EN
- Created: 01 Dec 2014
- 332 KB
Publication Part Number | 5991-3364EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for the analysis of BTEX in Air using the Agilent 490 Micro GC
- Publication Part Number: 5990-9527EN
- Created: 13 Feb 2014
- 501 KB
Publication Part Number | 5990-9527EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four solvents in a gas mix in 220 seconds.
- Publication Part Number: A0888
- Created: 31 Oct 2013
- 408 KB
Publication Part Number | A00888 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机This application note highlights percentage level analysis of hydrogen on an Agilent Micro GC using a mixed carrier gas.
- Publication Part Number: 5991-3199EN
- Created: 24 Oct 2013
- 761 KB
Publication Part Number | 5991-3199EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机This note describes the use of an Agilent 490-PRO Micro GC for the analysis of liquefied propane and butane (LPG) streams for plant quality control and plant processing.
- Publication Part Number: 5991-1972EN
- Created: 11 Mar 2013
- 449 KB
Publication Part Number | 5991-1972EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机This application note describes the use of the Agilent 490-PRO Micro GC for the analysis of liquefied ethane product.
- Publication Part Number: 5991-1817EN
- Created: 25 Jan 2013
- 527 KB
Publication Part Number | 5991-1817EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
Gas chromatography is a proven technology to analyze natural gas and its impurities.
- Publication Part Number: 5991-1190EN
- Created: 18 Dec 2012
- 692 KB
Publication Part Number | 5991-1190EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Bulk gaseous chemicals are not necessarily used close to their production site.
- Publication Part Number: 5991-1326EN
- Created: 23 Oct 2012
- 1 MB
Publication Part Number | 5991-1326EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Analysis of dichloromethane in waste water using the 490 Micro GC.
- Publication Part Number: SI-02642
- Created: 27 Sep 2012
- 722 KB
Publication Part Number | SI-02642 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
Publication Part Number | SI-02235 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
This application note demonstrates the capabilities of the COX column with the 490 Micro GC.
- Publication Part Number: 5990-7054EN
- Created: 06 Sep 2012
- 610 KB
Publication Part Number | 5990-7054EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Detection limits can be improved if analytes are concentrated before being injected onto the Agilent 490 Micro GC.
- Publication Part Number: 5991-0819EN
- Created: 19 July 2012
- 2 MB
Publication Part Number | 5991-0819EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机This application note describes a method for fast on-site analysis of mine gases in less than 100 seconds using the Agilent 490 Micro GC.
- Publication Part Number: 5991-0438EN
- Created: 06 June 2012
- 753 KB
Publication Part Number | 5991-0438EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机This application note shows the analysis of biogas, and related samples, using the Agilent 490 Micro GC Biogas Analyzer.
- Publication Part Number: 5990-9508EN
- Created: 22 Nov 2011
- 253 KB
Publication Part Number | 5990-9508EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|---|
Korean (Korea) | Complete (PDF) |
必威体育登录手机Fast GC analysis of inert gases in less than 150 seconds is achieved using an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC.
- Publication Part Number: A01633
- Created: 31 Oct 2011
- 407 KB
Publication Part Number | A01633 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01243
- Created: 31 Oct 2011
- 355 KB
Publication Part Number | A01243 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC analyzes nitrous oxide in air in 35 seconds.
- Publication Part Number: A01244
- Created: 31 Oct 2011
- 339 KB
Publication Part Number | A01244 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|