Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Compounds
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates trace halogenated hydrocarbons in acetaldehyde in 40 minutes.
- Publication Part Number: A01357
- Created: 31 Oct 2011
- 531 KB
Publication Part Number | A01357 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates halogenated hydrocarbons and C2 hydrocarbons in 15 minutes.
- Publication Part Number: A01356
- Created: 31 Oct 2011
- 634 KB
Publication Part Number | A01356 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column analyzes carbon dioxide and carbon monoxide in hydrocarbon streams in six minutes.
- Publication Part Number: A01431
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A01431 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates four C1 to C4 hydrocarbons in two minutes at 30 oC and 1 minute at 60 oC.
- Publication Part Number: A0685
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00685 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|