必威体育登录手机Gas chromatography using an Agilent CP-Sil 8 CB column separates ten chlorinated solvents in nine minutes
- Publication Part Number: A00720
- Created: 23 June 2014
- 708 KB
Publication Part Number | A00720 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four solvents in a gas mix in 220 seconds.
- Publication Part Number: A0888
- Created: 31 Oct 2013
- 408 KB
Publication Part Number | A00888 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 11 solvents in four minutes.
- Publication Part Number: A0438
- Created: 31 Oct 2011
- 718 KB
Publication Part Number | A00438 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 19 solvents in 30 minutes.
- Publication Part Number: A0718
- Created: 31 Oct 2011
- 862 KB
Publication Part Number | A00718 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of 26 solvents used in inks is accomplished in 35 minutes with an Agilent J&W Select 624 CB column.
- Publication Part Number: A02233
- Created: 31 Oct 2011
- 742 KB
Publication Part Number | A02233 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The Agilent J&W VF-23ms GC phase is very stable and efficient at lower temperatures, showing high selectivity and inertness for solvent analysis.
- Publication Part Number: A01970
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A01970 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 19 solvents in 17 minutes.
- Publication Part Number: A0719
- Created: 31 Oct 2011
- 680 KB
Publication Part Number | A00719 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight impurities in acetone in ten minutes.
- Publication Part Number: A0170
- Created: 31 Oct 2011
- 430 KB
Publication Part Number | A00170 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The inertness of the Agilent PoraPLOT Q-HT guarantees a high response for polar compounds, also at low concentrations.
- Publication Part Number: A01300
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A01300 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Select 624 CB column separates 53 volatile organic compounds according to EPA 524 in 30 minutes.
- Publication Part Number: A01450
- Created: 31 Oct 2011
- 954 KB
Publication Part Number | A01450 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates ten solvents in five minutes.
- Publication Part Number: A0681
- Created: 31 Oct 2011
- 568 KB
Publication Part Number | A00681 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates eight volatile solvents in air in 120 seconds.
- Publication Part Number: A0879
- Created: 31 Oct 2011
- 432 KB
Publication Part Number | A00879 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Using Agilent PoraPLOT Q-HT columns water elutes very quickly from the hydrophobic porous polymers and can be analyzed directly without using titration techniques.
- Publication Part Number: A01301
- Created: 31 Oct 2011
- 574 KB
Publication Part Number | A01301 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 18 C1 to C11 volatile alcohols, ketones, and ethers in 20 minutes.
- Publication Part Number: A0157
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00157 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 36 solvents in 41 minutes.
- Publication Part Number: A01318
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01318 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q column separates six solvents in a test mixture in 16 minutes.
- Publication Part Number: A01126
- Created: 31 Oct 2011
- 477 KB
Publication Part Number | A01126 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates low concentrations of methanol and dichloromethane in acetone in 10 minutes.
- Publication Part Number: A00002
- Created: 31 Oct 2011
- 306 KB
Publication Part Number | A00002 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Si 5 CB column separates 35 solvents and contaminants in a sample of industrial waste water in 18 minutes.
- Publication Part Number: A01451
- Created: 31 Oct 2011
- 833 KB
Publication Part Number | A01451 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT Q column identifies water in 1,2-dichloroethane in less than three minutes.
- Publication Part Number: A01120
- Created: 31 Oct 2011
- 406 KB
Publication Part Number | A01120 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|