Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机Application note describes innovative method for the confirmation of fire accelerants using the Agilent Capillary Trap Sampler (CTS).
- Publication Part Number: 5991-3439EN
- Created: 12 Dec 2013
- 250 KB
Publication Part Number | 5991-3439EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates over 165 C4 to C12 hydrocarbons in 130 minutes.
- Publication Part Number: A00602
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00602 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Squalene column separates isothermally 76 C1 to C9 aliphatic and cyclic hydrocarbons in naphtha in 28 minutes.
- Publication Part Number: A0434
- Created: 31 Oct 2011
- 912 KB
Publication Part Number | A00434 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates 111 C4 to C11 hydrocarbons in 49 minutes.
- Publication Part Number: A0903
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00903 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 111components during naphtha and reformate according to ASTM D5134 in 75 minutes.
- Publication Part Number: A0752
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00752 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Squalene column separates 76 C1 to C9 aliphatic and cyclic hydrocarbons in naphtha in 45 minutes.
- Publication Part Number: A0433
- Created: 31 Oct 2011
- 931 KB
Publication Part Number | A00433 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|