Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Detection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Agilent J&W CP-Sil 5 CB GC column separates C1 to C4 alkanes, hydrogen sulfide and other components of natural gas
- Publication Part Number: A00001
- Created: 12 Aug 2013
- 537 KB
Publication Part Number | A00001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 18 solvents in less than 11 minutes.
- Publication Part Number: A01563
- Created: 31 Oct 2011
- 584 KB
Publication Part Number | A01563 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 111components during naphtha and reformate according to ASTM D5134 in 75 minutes.
- Publication Part Number: A0752
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00752 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 25 impurities in 1,3-butadiene for an ASTM method, in 30 minutes.
- Publication Part Number: A01544
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A01544 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column separates 25 impurities in 1,3-butadiene for an ASTM method.
- Publication Part Number: A01545
- Created: 31 Oct 2011
- 710 KB
Publication Part Number | A01545 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C3 to C4 impurities in 1,2-butadiene in 20 minutes.
- Publication Part Number: A00594
- Created: 31 Oct 2011
- 774 KB
Publication Part Number | A00594 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 14 C1 to C6 hydrocarbon impurities in propylene in 20 minutes.
- Publication Part Number: A01097
- Created: 31 Oct 2011
- 613 KB
Publication Part Number | A01097 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates eight C1 to C4 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0606
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00606 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates 13 chlorinated fluorocarbons and C1 to C6 hydrocarbons in 15 minutes.
- Publication Part Number: A01429
- Created: 31 Oct 2011
- 721 KB
Publication Part Number | A01429 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent CP-Al2O3/KCl column separates 16 C1 to C4 hydrocarbons in 100 seconds.
- Publication Part Number: A0273
- Created: 31 Oct 2011
- 614 KB
Publication Part Number | A00273 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column indentifies 19 C1 to C7 hydrocarbons in 63 minutes.
- Publication Part Number: A0896
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A00896 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 32 solvents in 44 minutes, according to USP 467.
- Publication Part Number: A01546
- Created: 31 Oct 2011
- 892 KB
Publication Part Number | A01546 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight gases and volatiles in 13 minutes.
- Publication Part Number: A01610
- Created: 31 Oct 2011
- 409 KB
Publication Part Number | A01610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C1 to C4 light hydrocarbons in 20 minutes.
- Publication Part Number: A00591
- Created: 31 Oct 2011
- 376 KB
Publication Part Number | A00591 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C3 to C4 impurities in trans-2-butene in 15 minutes.
- Publication Part Number: A00595
- Created: 31 Oct 2011
- 702 KB
Publication Part Number | A00595 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 15 C1 to C6 hydrocarbon impurities in propylene in 15 minutes.
- Publication Part Number: A01098
- Created: 31 Oct 2011
- 738 KB
Publication Part Number | A01098 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 31components in unleaded gasoline according to ASTM D5769 in 58 minutes.
- Publication Part Number: A01274
- Created: 31 Oct 2011
- 874 KB
Publication Part Number | A01274 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column provides high resolution of 14 C1 to C4 hydrocarbons in seven minutes.
- Publication Part Number: A1095
- Created: 31 Oct 2011
- 561 KB
Publication Part Number | A01095 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q column separates 11 C1 to C6 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0607
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A00607 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
Publication Part Number | A00755 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|