Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Instrument
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 21 phenols according to EPA 8040 in 24 minutes.
- Publication Part Number: A1001
- Created: 31 Oct 2013
- 692 KB
Publication Part Number | A01001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
Publication Part Number | 5991-2153EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Using the Agilent 7696A Sample Prep WorkBench to prepare calibration standards
- Publication Part Number: 5991-0973EN
- Created: 17 Aug 2012
- 684 KB
Publication Part Number | 5991-0973EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Japanese (Japan) | Complete (PDF) |
必威体育登录手机Application note for the determination of Phenols in Drinking Water with Agilent Bond Elut Plexa SPE and HPLC
- Publication Part Number: 5990-9730EN
- Created: 06 Jan 2012
- 58 KB
Publication Part Number | 5990-9730EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using an Agilent J&W VF-Xms column separates 21 phenols in eight minutes.
- Publication Part Number: A01965
- Created: 31 Oct 2011
- 904 KB
Publication Part Number | A01965 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC analysis of 21 phenols with an Agilent J&W VF-200ms column achieves a separation in 22 minutes.
- Publication Part Number: A02201
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A02201 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Phenols are analyzed by GC according to EPA 8040A using the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- Publication Part Number: A02284
- Created: 31 Oct 2011
- 869 KB
Publication Part Number | A02284 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with Agilent J&W CP-Sil 8 CB and CP- 5 CB columns separate 33 methyl-, nitro, and chlorophenols in river water in 35 minutes.
- Publication Part Number: A0339
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00339 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 21 chlorinated phenols according to EPA 8040 in 20 minutes.
- Publication Part Number: A0912
- Created: 31 Oct 2011
- 712 KB
Publication Part Number | A00912 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 21 phenols according to EPA 8040 in 15 minutes.
- Publication Part Number: A0794
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A00794 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Inertness of the Agilent J&W VF-5ms GC column is very high, as shown in the GC/MS analysis of 21 free phenols in 12 minutes, using the EPA 528 method.
- Publication Part Number: A01984
- Created: 31 Oct 2011
- 730 KB
Publication Part Number | A01984 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00789 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|