Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
note cites and is supported by a VOC kit that contains the necessary parts to implement this VOC solution set.
- Publication Part Number: 5991-0029EN
- Created: 23 June 2015
- 4 MB
Publication Part Number | 5991-0029EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Volatile (vapor-phase) organic air toxics ‘Hazardous Air Pollutants' (HAPS) in many industrial & urban environments as a measure of air quality.
- Publication Part Number: 5991-2826EN
- Created: 26 July 2013
- 830 KB
Publication Part Number | 5991-2826EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|
Analyzing landfill site odors and toxic volatile compounds using a time dependent process.
- Publication Part Number: 5991-2825EN
- Created: 26 July 2013
- 3 MB
Publication Part Number | 5991-2825EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|
EPA Method TO-17 for monitoring ‘air toxics' in ambient air using sorbent tubes and automated, cryogenfree thermal desorption.
- Publication Part Number: 5991-2828EN
- Created: 26 July 2013
- 2 MB
Publication Part Number | 5991-2828EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
Chinese (Simplified) (China) | Complete (PDF) |
Using the CIA Advantage is an advanced system for the automated analysis of VOCs in air or gas samples using canisters
- Publication Part Number: 5991-2842EN
- Created: 26 July 2013
- 2 MB
Publication Part Number | 5991-2842EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Analysis of canister air samples using cryogen-free thermal desorption in compliance with US EPA method TO-15
- Publication Part Number: 5991-2829EN
- Created: 26 July 2013
- 2 MB
Publication Part Number | 5991-2829EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机An Agilent 7890 Series GC configured with an HPLI with post-column backflushing improves the analysis of trace hydrocarbon impurities in monomer grade 1,3-Butadiene.
- Publication Part Number: 5991-1672EN
- Created: 18 Dec 2012
- 1 MB
Publication Part Number | 5991-1672EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
An improved gas chromatographic method based on a 7890 Series GC for the analysis of trace hydrocarbon impurities in monomer grade 1, 3-Butadiene has been developed.
- Publication Part Number: 5991-1499EN
- Created: 29 Nov 2012
- 2 MB
Publication Part Number | 5991-1499EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Bulk gaseous chemicals are not necessarily used close to their production site.
- Publication Part Number: 5991-1326EN
- Created: 23 Oct 2012
- 1 MB
Publication Part Number | 5991-1326EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
Publication Part Number | SI-02644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
Acetylene, methylacetylene, and propadiene impurities, among others, are present in propylene.Specifications are set on these polar hydrocarbons.必威体育登录手机The Agilent J&W Select Al2O3
- Publication Part Number: A02036
- Created: 31 Oct 2011
- 634 KB
Publication Part Number | A02036 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- Publication Part Number: A02037
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02037 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 11 C1 to C4 alkanes and alkenes in 15 minutes.
- Publication Part Number: A00022
- Created: 31 Oct 2011
- 488 KB
Publication Part Number | A00022 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|