Refine Results
- 必威体育赛事投注
-
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
- Instrument
-
必威体育登录手机Agilent 7683B Automatic Liquid sampler (3)
必威体育登录手机Agilent 7683 Automatic Liquid sampler (3)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机This application note uses Agilent QuEChERS kits for fast sample preparation, resulting in excellent pesticide recoveries.必威体育登录手机Extraction efficiency with high recoveries was achieved for over 200 pesticides in tomatoes on the Agilent 7000D GC/TQ.
- Publication Part Number: 5994-4384EN
- Created: 23 Jan 2023
- 858 KB
This application note presents the development and optimization of a multiresidue method for the analysis of pesticide residues in cinnamon powder.
- Publication Part Number: 5994-5671EN
- Created: 18 Jan 2023
- 887 KB
必威体育登录手机A method for determination of volatile organic compounds in soil and sediment by Agilent 7890B GC/MSD
- Publication Part Number: 5994-0489EN
- Created: 20 Apr 2020
- 405 KB
必威体育登录手机Describes method translation for accelerated quantitation of semivolatile organic compounds on the Agilent Intuvo 9000 GC.
- Publication Part Number: 5994-0209EN
- Created: 30 Aug 2018
- 718 KB
A method of rthe analysis of benzene and derivatives in envrionmental water samples with Intuvo 9000 GC.
- Publication Part Number: 5994-0014EN
- Created: 06 July 2018
- 772 KB
Updated method for the Analysis of Nitrosamines in Drinking Water Using a GC-MS/MS (EEA 521.1) - Meeting Equivalence to EPA Method 521
- Publication Part Number: 5991-9224EN
- Created: 07 May 2018
- 969 KB
This note describes the quantitative analysis of pesticide residue in bovine milk listed on brazilian national plan and codex alimentarius.
- Publication Part Number: 5991-6916EN
- Created: 04 May 2016
- 295 KB
note cites and is supported by a VOC kit that contains the necessary parts to implement this VOC solution set.
- Publication Part Number: 5991-0029EN
- Created: 23 June 2015
- 4 MB
Publication Part Number | 5991-0029EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
A modified Bond Elut QuEChERS method was validated for the extraction of 27 pesticide residues from a high lipid olive matrix prior to GC/MS/MS.
- Publication Part Number: 5991-4800EN
- Created: 18 June 2014
- 316 KB
Publication Part Number | 5991-4800EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机An Agilent 7890B GC system configured with three detectors was used for the analysis of pesticides in water.
- Publication Part Number: 5991-2787EN
- Created: 05 Aug 2013
- 1 MB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Flow path inertness is critical in pesticide analysis for accuracy and precision
- Publication Part Number: 5991-1862EN
- Created: 21 Mar 2013
- 779 KB
Publication Part Number | 5991-1862EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Flow path inertness is critical in pesticide analysis accuracy and precision, especially for active analytes such as organophosphate pesticides.
- Publication Part Number: 5991-1860EN
- Created: 13 Mar 2013
- 1 MB
Publication Part Number | 5991-1860EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
A method was developed on the 7890A Series GC and an 7000B Triple Quadrupole GC/MS mass spectrometer in PCI mode that provides sensitivity of ppt and lower for NDMA.
- Publication Part Number: 5991-1801EN
- Created: 22 Jan 2013
- 258 KB
Publication Part Number | 5991-1801EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
DB-UI 8270D 0.18 mm id (with Ultra Inert liners) and 0.25 mm id columns provided excellent peak shapes and performance for semi-volatile water pollutants.
- Publication Part Number: 5991-0250EN
- Created: 24 Aug 2012
- 770 KB
Publication Part Number | 5991-0250EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Compared to other vendor's columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
Publication Part Number | 5991-0615EN | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
Sample Matrix |
|
Application note for sub μg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/μECD
- Publication Part Number: 5990-9735EN
- Created: 20 Jan 2012
- 1 MB
Publication Part Number | 5990-9735EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for Organophosphorus Pesticides in Apple Matrix by GC/MS/FPD using an Agilent J&W DB-35ms Ultra Inert GC Column
- Publication Part Number: 5990-7165EN
- Created: 06 Jan 2012
- 841 KB
Publication Part Number | 5990-7165EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Application note for the determination of Haloacetic Acids in Water by GC/μECD Using Agilent J&W DB-35ms Ultra Inert and DB-XLB Columns
- Publication Part Number: 5990-8765EN
- Created: 15 Aug 2011
- 625 KB
Publication Part Number | 5990-8765EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
The QuEChERS method for pesticide analysis was first introduced by USDA scientists in 2003...
- Publication Part Number: 5990-8108EN
- Created: 16 May 2011
- 142 KB
Publication Part Number | 5990-8108EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for organophosphorus residues in Olive Oil by GC/FPD with Agilent J&W DB-35ms Ultra Inert
- Publication Part Number: 5990-7722EN
- Created: 21 Apr 2011
- 1 MB
Publication Part Number | 5990-7722EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|