必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 29 pesticides according to EPA 508 in 64 minutes.
- Publication Part Number: A0780
- Created: 31 Oct 2011
- 551 KB
Publication Part Number | A00780 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 16 organochlorine pesticides according to EPA625 in 27 minutes.
- Publication Part Number: A02092
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A02092 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00789 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W VF-Xms column separates 16 chlorinated pesticides in under ten minutes.
- Publication Part Number: A01990
- Created: 31 Oct 2011
- 605 KB
Publication Part Number | A01990 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 15 chlorinated pesticides in 15 minutes.
- Publication Part Number: A0360
- Created: 31 Oct 2011
- 942 KB
Publication Part Number | A00360 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 15 organochlorine pesticides in 39 minutes.
- Publication Part Number: A1092
- Created: 31 Oct 2011
- 672 KB
Publication Part Number | A01092 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of halogenated pesticides uses direct injection and the stabilized 50% phenyl PDMS of an Agilent J&W VF-17ms column.
- Publication Part Number: A02297
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A02297 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 23 pesticides and polychlorinated biphenyls in a standard mixture in 26 minutes.
- Publication Part Number: A0478
- Created: 31 Oct 2011
- 699 KB
Publication Part Number | A00478 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 15 organochlorine pesticides in 27 minutes.
- Publication Part Number: A1091
- Created: 31 Oct 2011
- 707 KB
Publication Part Number | A01091 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 12 organochlorine components in toxaphene according to EPA 8080 in 55 minutes.
- Publication Part Number: A0799
- Created: 31 Oct 2011
- 602 KB
Publication Part Number | A00799 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 24 CB column separates 19 pesticides in 35 minutes.
- Publication Part Number: A1004
- Created: 31 Oct 2011
- 806 KB
Publication Part Number | A01004 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates four hexachlorocyclohexane isomers in 10 minutes.
- Publication Part Number: A00070
- Created: 31 Oct 2011
- 369 KB
Publication Part Number | A00070 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 27 chloropesticides and polychlorinated biphenyls in 22 minutes.
- Publication Part Number: A00596
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A00596 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Exploring techniques for determining chemical contaminants in marine shellfish using the Agilent 7000 Triple Quadrupole GC/MS System.
- Publication Part Number: 5990-7714EN
- Created: 06 Apr 2011
- 857 KB
Publication Part Number | 5990-7714EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W VF-1701ms column analyzes 16 EPA 625 halogenated pesticides using ECD at 2 and 200 pg.
- Publication Part Number: A02393
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02393 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Trace analysis of 17 pesticides using the Agilent J&W VF-17ms in 26 minutes.
- Publication Part Number: A02346
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02346 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机최저 5ppb 수준, SVOC 30종 검출을 위해 Agilent 5977A 시리즈 GC/MSD로 개발한 분석법은 뛰어난 직선성 및 재현성을 가집니다.
- Publication Part Number: 5991-2127KO
- Created: 05 Mar 2019
- 2 MB
Publication Part Number | 5991-2127EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|