Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using Agilent J&W CP-Sil 5 CB and CP-Sil 8 CB columns separates 32 components from the thermal desorption of a potential oil-bearing rock.
- Publication Part Number: A00059
- Created: 31 Oct 2013
- 827 KB
Publication Part Number | A00059 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB Low Bleed/MS column separates 35components in a beech leaf cuticular wax in 70 minutes.
- Publication Part Number: A01234
- Created: 31 Oct 2011
- 722 KB
Publication Part Number | A01234 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 34 constituents from a total lipid extract from a fossil leaf of Pseudofagus idahoensis, as TMS derivative
- Publication Part Number: A0759
- Created: 31 Oct 2011
- 636 KB
Publication Part Number | A00759 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist CB column separates 11 components of mineral oil in a soil sample in less than 15 minutes.
- Publication Part Number: A01105
- Created: 31 Oct 2011
- 505 KB
Publication Part Number | A01105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates trisilylimidazole/BSTFA sugar derivatives in hexane in 30 minutes.
- Publication Part Number: A01328
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A01328 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 28 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01421
- Created: 31 Oct 2011
- 819 KB
Publication Part Number | A01421 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SimDist CB UltiMetal column analyzes reference gas oil according to ASTM D2887 in 30 minutes.
- Publication Part Number: A01262
- Created: 31 Oct 2011
- 824 KB
Publication Part Number | A01262 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates C5 to C44 hydrocarbons in a standard mixture in 36 minutes.
- Publication Part Number: A0651
- Created: 31 Oct 2011
- 730 KB
Publication Part Number | A00651 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 components in a sample of crude oil in 50 minutes.
- Publication Part Number: A00096
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A00096 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 23 substituted aromatic hydrocarbons in a sample of diesel oil in 20 minutes.
- Publication Part Number: A0199
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00199 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 37 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01420
- Created: 31 Oct 2011
- 873 KB
Publication Part Number | A01420 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column identifies trace methanol in a hydrocarbon matrix in 25 minutes.
- Publication Part Number: A01363
- Created: 31 Oct 2011
- 862 KB
Publication Part Number | A01363 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates C18 to C80 components in Polywax 500 over gasoil sample in 36 minutes.
- Publication Part Number: A0754
- Created: 31 Oct 2011
- 890 KB
Publication Part Number | A00754 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five anabolic steroids in urine in 20 minutes.
- Publication Part Number: A00058
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00058 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates 16 C8 to C40 hydrocarbons in 12 minutes.
- Publication Part Number: A0998
- Created: 31 Oct 2011
- 604 KB
Publication Part Number | A00998 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-SimDist UltiMetal column separate hydrocarbons according to IP PM-CX/98.
- Publication Part Number: A01335
- Created: 31 Oct 2011
- 956 KB
Publication Part Number | A01335 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- Publication Part Number: A01617
- Created: 31 Oct 2011
- 489 KB
Publication Part Number | A01617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist Ultimetal column separates 15 C10 to C44 hydrocarbons in a standard test mix in 18 minutes.
- Publication Part Number: A0605
- Created: 31 Oct 2011
- 803 KB
Publication Part Number | A00605 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 27semivolatiles in indoor air in 40 minutes.
- Publication Part Number: A01901
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01901 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates nine oxygenates in 16 minutes.
- Publication Part Number: A01830
- Created: 01 Oct 2011
- 893 KB
Publication Part Number | A01830 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|