必威体育登录手机Agilent J&W HP-PLOT Q PT and HP-PLOT U PT GC columns were evaluated for coal-to-chemical process gas analysis by GC/TCD and GC/MS detection.
- Publication Part Number: 5991-2205EN
- Created: 03 Apr 2013
- 262 KB
Publication Part Number | 5991-2205EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
Publication Part Number | A00755 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates carbonyl sulfide and ethylene in seven minutes.
- Publication Part Number: A01260
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A01260 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS analysis of C2 to C3 hydrocarbons in air is achieved in 5.5 minutes with an Agilent J&W CarboBOND column.
- Publication Part Number: A01925
- Created: 01 Oct 2011
- 686 KB
Publication Part Number | A01925 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机GC/MS analysis of chlorinated impurities in ethylene is achieved in 10 minutes with an Agilent J&W CarboBOND column.
- Publication Part Number: A01924
- Created: 01 Oct 2011
- 655 KB
Publication Part Number | A01924 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|