Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Instrument
- Method
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of Carnauba Wax using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01129
- Created: 03 Feb 2014
- 189 KB
Publication Part Number | SI-01129 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of 370-550 C Petroleum Fraction using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01316
- Created: 29 Jan 2014
- 147 KB
Publication Part Number | SI-01316 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of Fluid Cat Cracker Feed using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01130
- Created: 29 Jan 2014
- 195 KB
Publication Part Number | SI-01130 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the separation of four Anti Slip Agents
- Publication Part Number: SI-02065
- Created: 29 Jan 2014
- 263 KB
Publication Part Number | SI-02065 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Analysis of polymer additives in plastics using a VF-5ht UltiMetal column.
- Publication Part Number: SI-02042
- Created: 27 Sep 2012
- 332 KB
Publication Part Number | SI-02042 | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
示例矩陣 |
|
JK
- Publication Part Number: SI-02105
- Created: 05 Dec 2011
- 467 KB
Publication Part Number | SI-02105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Sil 5 column separates 11 pesticides in 17 minutes.
- Publication Part Number: A0123
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A00123 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Sil 8 column separates 20 polycyclic aromatic hydrocarbons in 20 minutes.
- Publication Part Number: A0125
- Created: 31 Oct 2011
- 847 KB
Publication Part Number | A00125 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 C24 to C56 triglycerides in 14 minutes.
- Publication Part Number: A0707
- Created: 31 Oct 2011
- 798 KB
Publication Part Number | A00707 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Determine cholesterol, beta-sitosterol and stigmasterol in butter fat by GC with an Agilent J&W VF-5ms column.
- Publication Part Number: A02255
- Created: 31 Oct 2011
- 947 KB
Publication Part Number | A02255 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column identifies cholesterol and C48 to C56 triglycerides in egg yolk in 16 minutes.
- Publication Part Number: A0240
- Created: 31 Oct 2011
- 359 KB
Publication Part Number | A00240 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Chirasil-DEX CB column separates eight underivatized, enantiomeric isomers of carboxylic acids in 33 minutes.
- Publication Part Number: A01438
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A01438 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of lubricating oil contamination in under ten minutes using an Agilent J&W Select Mineral Oil column according to DIN EN ISO 9377-2.
- Publication Part Number: A02048
- Created: 31 Oct 2011
- 684 KB
Publication Part Number | A02048 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten sugars as their TMS derivatives in 60 seconds.
- Publication Part Number: A0708
- Created: 31 Oct 2011
- 578 KB
Publication Part Number | A00708 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates 17 triglycerides in soya bean oil in 17 minutes.
- Publication Part Number: A00224
- Created: 31 Oct 2011
- 539 KB
Publication Part Number | A00224 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The analysis of mineral oil to DIN EN ISO 9377-2 is accomplished by GC with an Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02045
- Created: 31 Oct 2011
- 726 KB
Publication Part Number | A02045 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SimDist UltiMetal column separates C24 to C54 triglycerides in 40 minutes.
- Publication Part Number: A01439
- Created: 31 Oct 2011
- 643 KB
Publication Part Number | A01439 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates 30 C50 to C62 triglycerides in peanut oil in 16 minutes.
- Publication Part Number: A0233
- Created: 31 Oct 2011
- 552 KB
Publication Part Number | A00233 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates 11 aromatics in 15 minutes.
- Publication Part Number: A0111
- Created: 31 Oct 2011
- 592 KB
Publication Part Number | A00111 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|