Refine Results
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
- Compounds
-
- Language
-
Language
Applied Filters
必威体育登录手机Extended simulated distillation of a ‘polluted' motor oil according to D2887 with an Agilent J&W CP-SimDist UltiMetal column.
- Publication Part Number: A02261
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02261 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SimDist CB UltiMetal separates light, medium and heavy fractions according to ASTM D2887 in 30 minutes.
- Publication Part Number: A01263
- Created: 31 Oct 2011
- 413 KB
Publication Part Number | A01263 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Extended simulated distillation of a motor oil according to D2887 with an Agilent J&W CP-SimDist UltiMetal column.
- Publication Part Number: A02262
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02262 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SimDist CB UltiMetal column analyzes reference gas oil according to ASTM D2887 in 30 minutes.
- Publication Part Number: A01262
- Created: 31 Oct 2011
- 824 KB
Publication Part Number | A01262 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Boiling point analysis of sulfur compounds in hydrogenated naphtha by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01812
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01812 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Boiling point analysis of sulfur compounds in cracked gasoil by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01811
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01811 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|