Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six impurities in vinylchloride in two minutes.
- Publication Part Number: A0275
- Created: 31 Oct 2011
- 314 KB
Publication Part Number | A00275 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column module and Agilent 490 Micro GC analyzes CFC 113 in air 17 seconds.
- Publication Part Number: A0873
- Created: 31 Oct 2011
- 373 KB
Publication Part Number | A00873 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates seven chlorinated fluorocarbons in 13 minutes.
- Publication Part Number: A01446
- Created: 31 Oct 2011
- 795 KB
Publication Part Number | A01446 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC analyzes CFC 113 in air in 70 seconds.
- Publication Part Number: A0880
- Created: 31 Oct 2011
- 369 KB
Publication Part Number | A00880 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2SO3/Na2SO4 column separates seven chlorinated fluorocarbons in 20 minutes.
- Publication Part Number: A01447
- Created: 31 Oct 2011
- 631 KB
Publication Part Number | A01447 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module detects CFC 22 (CHF2Cl2) in air in 14 seconds.
- Publication Part Number: A0884
- Created: 31 Oct 2011
- 388 KB
Publication Part Number | A00884 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates three C2 halogenated hydrocarbons in water in 40 minutes.
- Publication Part Number: A1018
- Created: 31 Oct 2011
- 567 KB
Publication Part Number | A01018 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|