Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
必威体育登录手机The environment of the reactor in a nuclear power plant cnn be checked for the presence of gases with portable Agilent 490 Micro GC with Agilent J&W CP-Molsieve 5Å.
- Publication Part Number: A01621
- Created: 12 Aug 2022
- 241 KB
Publication Part Number | A01621 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four solvents in a gas mix in 220 seconds.
- Publication Part Number: A0888
- Created: 31 Oct 2013
- 408 KB
Publication Part Number | A00888 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC analyzes nitrous oxide in air in 35 seconds.
- Publication Part Number: A01244
- Created: 31 Oct 2011
- 339 KB
Publication Part Number | A01244 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates helium, oxygen, nitrogen, methane, hydrogen, and carbon monoxide in 70 s.
- Publication Part Number: A0870
- Created: 31 Oct 2011
- 352 KB
Publication Part Number | A00870 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Fast GC analysis of halogenated refrigerant mixtures is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01957
- Created: 31 Oct 2011
- 564 KB
Publication Part Number | A01957 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC detects low ppm levels of hydrogen in helium/neon in 30 seconds.
- Publication Part Number: A0864
- Created: 31 Oct 2011
- 255 KB
Publication Part Number | A00864 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC analyzes CFC 11 and CFC 123 in air in 23 seconds.
- Publication Part Number: A0881
- Created: 31 Oct 2011
- 329 KB
Publication Part Number | A00881 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four gases in air in 22 seconds.
- Publication Part Number: A00887
- Created: 31 Oct 2011
- 530 KB
Publication Part Number | A00887 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates hydrogen, oxygen, nitrogen, helium, and neon in 70 seconds.
- Publication Part Number: A0860
- Created: 31 Oct 2011
- 374 KB
Publication Part Number | A00860 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent CP-Molsieve 5Å column module and Agilent 490 Micro GC separates neon, nitrogen, hydrogen and argon in a xenon test mix in 66 seconds.
- Publication Part Number: A0871
- Created: 31 Oct 2011
- 441 KB
Publication Part Number | A00871 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Fast GC analysis of refrigerant impurities in CFC-143A is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01958
- Created: 31 Oct 2011
- 520 KB
Publication Part Number | A01958 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC detects oxygen, nitrogen, and methane at 100 ppm in 17 seconds.
- Publication Part Number: A0865
- Created: 31 Oct 2011
- 373 KB
Publication Part Number | A00865 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-COx column module and Agilent 490 Micro GC separates hydrogen, oxygen, nitrogen, carbon monoxide, carbon dioxide, and methane in 250
- Publication Part Number: A0907
- Created: 31 Oct 2011
- 542 KB
Publication Part Number | A00907 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机The Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separate oxygen, nitrogen, methane, carbon dioxide, and hydrogen in 30 seconds.
- Publication Part Number: A0855
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A00855 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC detects nitrous oxide in air in 25 seconds.
- Publication Part Number: A0882
- Created: 31 Oct 2011
- 289 KB
Publication Part Number | A00882 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机The Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separate oxygen, argon, carbon monoxide, hydrogen, nitrogen, and methane in helium in 95 s.
- Publication Part Number: A0862
- Created: 31 Oct 2011
- 330 KB
Publication Part Number | A00862 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机On-site air is monitored with Agilent 490 Micro GC and Agilent J&W CP-Sil 8 CB.Target components are aromatics, which can be measured within 150 s down to ppm.
- Publication Part Number: A01622
- Created: 31 Oct 2011
- 500 KB
Publication Part Number | A01622 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column module and Agilent 490 Micro GC separates nine chlorinated hydrocarbons in air in 130 seconds.
- Publication Part Number: A0872
- Created: 31 Oct 2011
- 418 KB
Publication Part Number | A00872 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-COx column module and Agilent 490 Micro GC analyzes carbon monoxide and carbon dioxide in 250 seconds.
- Publication Part Number: A0990
- Created: 31 Oct 2011
- 487 KB
Publication Part Number | A00990 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Fast GC analysis of inert gases in less than 150 seconds is achieved using an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC.
- Publication Part Number: A01633
- Created: 31 Oct 2011
- 407 KB
Publication Part Number | A01633 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|