Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates hydrogen chloride and sulfuryl chloride in less than five minutes.
- Publication Part Number: A01427
- Created: 31 Oct 2013
- 581 KB
Publication Part Number | A01427 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The Agilent J&W DB-Sulfur SCD column and Agilent 355 SCD deliver accurate quantitative and qualitative analysis of volatile sulfur compounds in petroleum samples.
- Publication Part Number: 5991-3108EN
- Created: 05 Sep 2013
- 401 KB
Publication Part Number | 5991-3108EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Agilent J&W CP-Sil 5 CB GC column separates C1 to C4 alkanes, hydrogen sulfide and other components of natural gas
- Publication Part Number: A00001
- Created: 12 Aug 2013
- 537 KB
Publication Part Number | A00001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC separation of 13 nitro and sulfur compounds according to EPA 8270 is achieved in 20 minutes with an J&W Agilent VF-17ms column.
- Publication Part Number: A02279
- Created: 31 Oct 2011
- 965 KB
Publication Part Number | A02279 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Fast GC analysis THT and MES in natural gas in three minutes, using an Agilent J&W Lowox column.
- Publication Part Number: A02249
- Created: 31 Oct 2011
- 823 KB
Publication Part Number | A02249 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column analyzes ethanethiol in a sample of liquid petroleum gas in four minutes.
- Publication Part Number: A01452
- Created: 31 Oct 2011
- 536 KB
Publication Part Number | A01452 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates three sulfur contaminants in natural gas in less than ten minutes.
- Publication Part Number: A01625
- Created: 31 Oct 2011
- 308 KB
Publication Part Number | A01625 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB UltiMetal column separates sulfur compounds in natural gas in eight minutes.
- Publication Part Number: A01296
- Created: 31 Oct 2011
- 597 KB
Publication Part Number | A01296 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 13 sulfur compounds in a wine in 33 minutes.
- Publication Part Number: A0444
- Created: 31 Oct 2011
- 602 KB
Publication Part Number | A00444 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC and a special column module determines 1-butyl mercaptane (TBM) in natural gas in
- Publication Part Number: A01236
- Created: 31 Oct 2011
- 320 KB
Publication Part Number | A01236 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates three aromatic sulfur compounds in 17 minutes.
- Publication Part Number: A0986
- Created: 31 Oct 2011
- 631 KB
Publication Part Number | A00986 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB for THT column module and Agilent 490 Micro GC separates tetrahydrothiophene in natural gas in 75 seconds.
- Publication Part Number: A01239
- Created: 31 Oct 2011
- 363 KB
Publication Part Number | A01239 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB for Sulfur column separates four sulfur compounds in ten minutes.
- Publication Part Number: A01258
- Created: 31 Oct 2011
- 369 KB
Publication Part Number | A01258 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of THT and TBM in natural gas in under two minutes using an Agilent J&W Lowox column.
- Publication Part Number: A02248
- Created: 31 Oct 2011
- 820 KB
Publication Part Number | A02248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 52 CB column identifies dimethylsulfide in a sample of beer in 15 minutes.
- Publication Part Number: A00006
- Created: 31 Oct 2011
- 449 KB
Publication Part Number | A00006 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist Ultimetal column separates 13 C12 to C60 waxes plus a sulfur standard in 16 minutes.
- Publication Part Number: A00589
- Created: 31 Oct 2011
- 501 KB
Publication Part Number | A00589 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates four trace sulfur compounds in eight minutes.
- Publication Part Number: A01458
- Created: 31 Oct 2011
- 503 KB
Publication Part Number | A01458 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-SilicaPLOT column separates seven sulfur compounds in 25 minutes.
- Publication Part Number: A01257
- Created: 31 Oct 2011
- 524 KB
Publication Part Number | A01257 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column identifies thiophene in a benzene sample in less than 15 minutes.
- Publication Part Number: A01350
- Created: 31 Oct 2011
- 844 KB
Publication Part Number | A01350 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 12 low-boiling, sulfur-containing compounds in 17 minutes.
- Publication Part Number: A0419
- Created: 31 Oct 2011
- 762 KB
Publication Part Number | A00419 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|