Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
-
必威体育登录手机Agilent 7000 Triple Quadrupole GC/MS (2)
Instrument
- Method
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of Carnauba Wax using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01129
- Created: 03 Feb 2014
- 189 KB
Publication Part Number | SI-01129 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of 370-550 C Petroleum Fraction using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01316
- Created: 29 Jan 2014
- 147 KB
Publication Part Number | SI-01316 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the separation of four Anti Slip Agents
- Publication Part Number: SI-02065
- Created: 29 Jan 2014
- 263 KB
Publication Part Number | SI-02065 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Application note for the analysis of Fluid Cat Cracker Feed using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01130
- Created: 29 Jan 2014
- 195 KB
Publication Part Number | SI-01130 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
A fast responding mobile solution from sampler to detector with small size and low power consumption is highly desirable for on-site air pollutant analysis.
- Publication Part Number: 5991-1500EN
- Created: 09 Nov 2012
- 688 KB
Publication Part Number | 5991-1500EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Russian (Russia) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Analysis of polymer additives in plastics using a VF-5ht UltiMetal column.
- Publication Part Number: SI-02042
- Created: 27 Sep 2012
- 332 KB
Publication Part Number | SI-02042 | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
示例矩陣 |
|
The VF-5ht UltiMetal column provides an unbreakable metal column with excellent inertness similar to fused silica tubing.
- Publication Part Number: SI-01317
- Created: 17 Sep 2012
- 195 KB
Publication Part Number | SI-01317 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
A novel sample preparation regime has been developed for the extraction and cleanup
- Publication Part Number: 5990-9865EN
- Created: 20 Aug 2012
- 2 MB
Publication Part Number | 5990-9865EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
JK
- Publication Part Number: SI-02105
- Created: 05 Dec 2011
- 467 KB
Publication Part Number | SI-02105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates 11 components in butter fat in 29 minutes.
- Publication Part Number: A0223
- Created: 31 Oct 2011
- 765 KB
Publication Part Number | A00223 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast analysis of diesel-contaminated samples is achieved by GC with the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02047
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02047 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of lubricating oil contamination in under ten minutes using an Agilent J&W Select Mineral Oil column according to DIN EN ISO 9377-2.
- Publication Part Number: A02048
- Created: 31 Oct 2011
- 684 KB
Publication Part Number | A02048 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 12 C5 to C8 alcohols in 25 minutes.
- Publication Part Number: A01107
- Created: 31 Oct 2011
- 317 KB
Publication Part Number | A01107 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates 12 C28 to C54 triglycerides in coconut oil in 29 minutes.
- Publication Part Number: A0249
- Created: 31 Oct 2011
- 720 KB
Publication Part Number | A00249 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 C10 to C16 alkanes in 15 minutes.
- Publication Part Number: A00087
- Created: 31 Oct 2011
- 659 KB
Publication Part Number | A00087 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB Low Bleed/MS column separates 35components in a beech leaf cuticular wax in 70 minutes.
- Publication Part Number: A01234
- Created: 31 Oct 2011
- 722 KB
Publication Part Number | A01234 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates eight C28 to C56 triglycerides in hydrogenated butter fat in 30 minutes.
- Publication Part Number: A0250
- Created: 31 Oct 2011
- 933 KB
Publication Part Number | A00250 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates 30 C50 to C62 triglycerides in peanut oil in 16 minutes.
- Publication Part Number: A0233
- Created: 31 Oct 2011
- 552 KB
Publication Part Number | A00233 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates four additives in polyethylene glycol in 22 minutes.
- Publication Part Number: A0749
- Created: 31 Oct 2011
- 481 KB
Publication Part Number | A00749 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|