Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates two N-trifluoroacetyl derivatives of threonine propyl esters in 22 minutes.
- Publication Part Number: A01117
- Created: 19 July 2016
- 54 KB
Publication Part Number | A01117 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of eight gamma-lactones in 35 minutes.
- Publication Part Number: A0969
- Created: 31 Oct 2011
- 587 KB
Publication Part Number | A00969 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of racemic alkyl bromides in 20 minutes.
- Publication Part Number: A0970
- Created: 31 Oct 2011
- 674 KB
Publication Part Number | A00970 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of racemic underivatized diols in 10 minutes.
- Publication Part Number: A0971
- Created: 31 Oct 2011
- 725 KB
Publication Part Number | A00971 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Chirasil-DEX CB column separates arabitol enantiomers as trifluoroacetyl derivatives in spinal fluid in 11 minutes.
- Publication Part Number: A01422
- Created: 31 Oct 2011
- 451 KB
Publication Part Number | A01422 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of six racemic aromatic alcohols (phenyl substituted alcohols) in 15 minutes.
- Publication Part Number: A0967
- Created: 31 Oct 2011
- 852 KB
Publication Part Number | A00967 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates two N-trifluoroacetyl derivatives of phenylalanine propyl esters in 27 minutes.
- Publication Part Number: A01118
- Created: 31 Oct 2011
- 340 KB
Publication Part Number | A01118 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates racemic aromatic alcohols in 14 minutes.
- Publication Part Number: A0975
- Created: 31 Oct 2011
- 600 KB
Publication Part Number | A00975 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an AgilentJ&W CP-Chirasil-DEX CB column separates three fluorotoluene isomers in 19 minutes.
- Publication Part Number: A01445
- Created: 31 Oct 2011
- 472 KB
Publication Part Number | A01445 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates 11 acetyl esters of branched C11 to C12 alcohols in 75 minutes.
- Publication Part Number: A01112
- Created: 31 Oct 2011
- 521 KB
Publication Part Number | A01112 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of chloroethylcyclohexane in six minutes.
- Publication Part Number: A0995
- Created: 31 Oct 2011
- 459 KB
Publication Part Number | A00995 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates nine branched C11 to C12 alcohols in 70 minutes.
- Publication Part Number: A01114
- Created: 31 Oct 2011
- 576 KB
Publication Part Number | A01114 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates four hexachlorocyclohexane pesticides in 36 minutes.
- Publication Part Number: A0997
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A00997 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Chirasil-DEX CB column separates 14 phenol and cresol isomers in ten minutes.
- Publication Part Number: A01449
- Created: 31 Oct 2011
- 591 KB
Publication Part Number | A01449 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of aromatic alcohols in 15 minutes.
- Publication Part Number: A0972
- Created: 31 Oct 2011
- 686 KB
Publication Part Number | A00972 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Chirasil-DEX CB column separates eight underivatized, enantiomeric isomers of carboxylic acids in 33 minutes.
- Publication Part Number: A01438
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A01438 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of seven underivatized diols in 20 minutes.
- Publication Part Number: A0968
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A00968 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Cyclodextrin-B-2,3,6-M-19 column separates optical isomers of methanol in 20 minutes.
- Publication Part Number: A01327
- Created: 31 Oct 2011
- 773 KB
Publication Part Number | A01327 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Chirasil-DEX CB column separates six N-trifluoroacetyl derivatives of alanine methyl, ethyl and propyl esters in 22 minutes.
- Publication Part Number: A01116
- Created: 31 Oct 2011
- 419 KB
Publication Part Number | A01116 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates eight N-trifluoroacetyl derivatives of amino acid propyl esters in 24 minutes.
- Publication Part Number: A01119
- Created: 31 Oct 2011
- 424 KB
Publication Part Number | A01119 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|