Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
- Injection Technique
- Method
- Language
-
Language
Applied Filters
必威体育登录手机Fast analysis of diesel-contaminated samples is achieved by GC with the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02047
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02047 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil or water is achieved in eight minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C10 to C40.
- Publication Part Number: A02016
- Created: 31 Oct 2011
- 587 KB
Publication Part Number | A02016 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机An oncolumn method for GC analysis of mineral oil in soil determines C10 up to C40 in less than three minutes using the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02026
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02026 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of lubricating oil contamination in under ten minutes using an Agilent J&W Select Mineral Oil column according to DIN EN ISO 9377-2.
- Publication Part Number: A02048
- Created: 31 Oct 2011
- 684 KB
Publication Part Number | A02048 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist CB column separates 11 components of mineral oil in a soil sample in less than 15 minutes.
- Publication Part Number: A01105
- Created: 31 Oct 2011
- 505 KB
Publication Part Number | A01105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机An oncolumn method is used for soil analysis by GC, allowing C10 to C40 to be determined in less than 5 minutes with Agilent J&W Select Mineral Oil.
- Publication Part Number: A01976
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A01976 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil is accomplished in four minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C10 to C40.
- Publication Part Number: A02020
- Created: 31 Oct 2011
- 833 KB
Publication Part Number | A02020 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The analysis of mineral oil to DIN EN ISO 9377-2 is accomplished by GC with an Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02045
- Created: 31 Oct 2011
- 726 KB
Publication Part Number | A02045 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil is accomplished in less than three minutes using the Agilent J&W Select Mineral Oil column, allowing determination of C10 to C40.
- Publication Part Number: A02025
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02025 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机For soil analysis, an oncolumn method analyzes C10 up to C40 in less than five minutes using the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02027
- Created: 31 Oct 2011
- 817 KB
Publication Part Number | A02027 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with Agilent J&W CP-Sil 5 CB Low Bleed/MS separates 14 components in a sample of mineral oil in 35 minutes, according to the Dutch standard NVN 6678.
- Publication Part Number: A01322
- Created: 31 Oct 2011
- 787 KB
Publication Part Number | A01322 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil is accomplished in six minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C10 to C50.
- Publication Part Number: A02024
- Created: 31 Oct 2011
- 822 KB
Publication Part Number | A02024 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机With large volume injection method, C10 to C40 mineral oils in water are determined in less than 15 minutes at ppb levels with Agilent J&W Select Mineral Oil.
- Publication Part Number: A01977
- Created: 31 Oct 2011
- 943 KB
Publication Part Number | A01977 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil is achieved in eight minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C20 to C40 oncolumn.
- Publication Part Number: A02023
- Created: 31 Oct 2011
- 785 KB
Publication Part Number | A02023 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil is accomplished in three minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C12 to C20.
- Publication Part Number: A02022
- Created: 31 Oct 2011
- 786 KB
Publication Part Number | A02022 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil is accomplished in four minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C12 to C25.
- Publication Part Number: A02021
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A02021 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The Agilent 1079 PTV injector with specially designed liner quantifies mineral oils down to ppb levels without preconcentration.
- Publication Part Number: A02460
- Created: 11 May 2010
- 2 MB
Publication Part Number | A02460 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Determination of hydrocarbons and lubricating oil in soil according to DIN H53 using an Agilent J&W VF-5ms GC column.
- Publication Part Number: A02332
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02332 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent 1079 PTV injector with optimized liner allows the quantitative determination of mineral oils down to ppb levels using the large volume injection technique.
- Publication Part Number: A02461
- Created: 11 May 2010
- 5 MB
Publication Part Number | A02461 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|