Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Injection Technique
- Method
-
- Language
-
Language
Applied Filters
必威体育登录手机Fast GC/MS with an Agilent J&W CP-Select 624 CB column separates 60 solvents in 16 minutes according to EPA 524.2.
- Publication Part Number: A01255
- Created: 31 Oct 2011
- 764 KB
Publication Part Number | A01255 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Select 624 CB column separates 53 volatile organic compounds according to EPA 524 in 30 minutes.
- Publication Part Number: A01450
- Created: 31 Oct 2011
- 954 KB
Publication Part Number | A01450 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Select 624 CB column separates 30 C1 to C6 halogenated hydrocarbons in 40 minutes according to EPA 601 and EPA 602.
- Publication Part Number: A01231
- Created: 31 Oct 2011
- 697 KB
Publication Part Number | A01231 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 26 pharmacopoeia-specified solvents in 30 minutes.
- Publication Part Number: A01304
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A01304 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Select 624 CB column separates 52 C1 to C6 halogenated hydrocarbons and aromatic hydrocarbons in 50 minutes.
- Publication Part Number: A01233
- Created: 31 Oct 2011
- 824 KB
Publication Part Number | A01233 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates five solvents in waste water in seven minutes.
- Publication Part Number: A0668
- Created: 31 Oct 2011
- 526 KB
Publication Part Number | A00668 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of 14 USP 467 solvents on an Agilent J&W VF-200ms column takes 15 minutes.
- Publication Part Number: A02204
- Created: 31 Oct 2011
- 540 KB
Publication Part Number | A02204 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Select 624 CB column separates 37 C1 to C6 halogenated hydrocarbons in 45 minutes.
- Publication Part Number: A01232
- Created: 31 Oct 2011
- 629 KB
Publication Part Number | A01232 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column identifies 15 components in a sample of water with organoleptic claims, in 22 minutes.
- Publication Part Number: A1014
- Created: 31 Oct 2011
- 540 KB
Publication Part Number | A01014 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Analysis of low levels of bromochloromethane in chloroform is done by GC/MS with Agilent J&W PoraBOND Q columns in 12 minutes.
- Publication Part Number: A01919
- Created: 01 Oct 2011
- 631 KB
Publication Part Number | A01919 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|