Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 14 halogenated hydrocarbons in a water sample in 15 minutes.
- Publication Part Number: A00071
- Created: 31 Oct 2011
- 516 KB
Publication Part Number | A00071 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 11C1 to C6 volatile halogenated hydrocarbons in nine minutes.
- Publication Part Number: A00016
- Created: 31 Oct 2011
- 441 KB
Publication Part Number | A00016 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 18 C1 to C7 halogenated hydrocarbons and aromatics in 11 minutes.
- Publication Part Number: A0179
- Created: 31 Oct 2011
- 657 KB
Publication Part Number | A00179 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six C1 halogenated methane hydrocarbons in six minutes.
- Publication Part Number: A00583
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00583 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|