Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Language
-
Language
Applied Filters
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using Agilent J&W CP-Sil 5 CB and CP-Sil 8 CB columns separates 32 components from the thermal desorption of a potential oil-bearing rock.
- Publication Part Number: A00059
- Created: 31 Oct 2013
- 827 KB
Publication Part Number | A00059 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine residual solvents in a sample of video tape in 70 minutes.
- Publication Part Number: A1047
- Created: 31 Oct 2011
- 673 KB
Publication Part Number | A01047 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a shampoo fingerprint in 45 minutes.
- Publication Part Number: A1040
- Created: 31 Oct 2011
- 747 KB
Publication Part Number | A01040 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 105 components in an apricot purée.
- Publication Part Number: A1023
- Created: 31 Oct 2011
- 3 MB
Publication Part Number | A01023 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column identifies 37 aromas from Chinese cabbage in 30 minutes.
- Publication Part Number: A1013
- Created: 31 Oct 2011
- 705 KB
Publication Part Number | A01013 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of Bulgarian rose oil in 40 minutes.
- Publication Part Number: A1039
- Created: 31 Oct 2011
- 745 KB
Publication Part Number | A01039 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 28 C1 to C6 halogenated hydrocarbons in drinking water in 20 minutes.
- Publication Part Number: A0303
- Created: 31 Oct 2011
- 309 KB
Publication Part Number | A00303 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates eight residual solvents in a sample of video tape in 70 minutes.
- Publication Part Number: A1048
- Created: 31 Oct 2011
- 671 KB
Publication Part Number | A01048 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column identifies geosmin and 2-methylisoborneol in surface water in 25 minutes.
- Publication Part Number: A1020
- Created: 31 Oct 2011
- 882 KB
Publication Part Number | A01020 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a deodorant fingerprint in 50 minutes.
- Publication Part Number: A1037
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A01037 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 10 components in a sample of a beefsteak plant (Perilla sp.) in 40 minutes.
- Publication Part Number: A1031
- Created: 31 Oct 2011
- 589 KB
Publication Part Number | A01031 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with TCT injection and an Agilent J&W CP-Sil 5 CB column identifies 39 trace components in air in 84 minutes.
- Publication Part Number: A0265
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00265 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column compares fingerprints of printed and unprinted polypropylene food wrapping in 25 minutes.
- Publication Part Number: A0373
- Created: 31 Oct 2011
- 515 KB
Publication Part Number | A00373 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-FFAP column produces a soap fingerprint in 50 minutes.
- Publication Part Number: A1041
- Created: 31 Oct 2011
- 742 KB
Publication Part Number | A01041 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of a draft beer in 45 minutes.
- Publication Part Number: A1024
- Created: 31 Oct 2011
- 534 KB
Publication Part Number | A01024 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 organic solvents in 35 minutes.
- Publication Part Number: A0493
- Created: 31 Oct 2011
- 671 KB
Publication Part Number | A00493 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of black sesame in 50 minutes.
- Publication Part Number: A1033
- Created: 31 Oct 2011
- 641 KB
Publication Part Number | A01033 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|