Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Method
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF
- Publication Part Number: 5991-4369EN
- Created: 02 May 2014
- 2 MB
Publication Part Number | 5991-4369EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
An analytical method that is well established for the 7000 Series Triple Quadrupole GC/MS has been employed to demonstrate performance of the 7000C Triple Quadrupole GC/MS.
- Publication Part Number: 5991-4131EN
- Created: 21 Mar 2014
- 180 KB
Publication Part Number | 5991-4131EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Fifteen days' exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
Publication Part Number | 5991-4110EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Mutants of the model cyanobacterium Synechococcus elongatus were evaluated by untargeted metabolomics to identify possible phenotypic changes that allow more efficient growth.
- Publication Part Number: 5991-3476EN
- Created: 05 Dec 2013
- 922 KB
Publication Part Number | 5991-3476EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机An Agilent 7890B GC system configured with three detectors was used for the analysis of pesticides in water.
- Publication Part Number: 5991-2787EN
- Created: 05 Aug 2013
- 1 MB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Non-targeted metabolomics analysis of opiate addiction in a murine model
- Publication Part Number: 5991-2481EN
- Created: 25 June 2013
- 3 MB
Publication Part Number | 5991-2481EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
Publication Part Number | 5991-2153EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A method has been developed on the Agilent 5977A Series GC/MSD that enables MDLs and RSDs for six phthalates
- Publication Part Number: 5991-1810EN
- Created: 26 Mar 2013
- 843 KB
Publication Part Number | 5991-1810EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A method has been developed on the Agilent 5977A Series GC/MSD System that can provide detection of N-nitrosamines in water at sub-part per trillion (ppt) levels
- Publication Part Number: 5991-1970EN
- Created: 12 Feb 2013
- 81 KB
Publication Part Number | 5991-1970EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|
必威体育登录手机USP residual solvents were analyzed by static headspace on the Agilent 7697A Headspace Sampler combined with the Agilent 7890B Gas Chromatograph.
- Publication Part Number: 5991-1834EN
- Created: 29 Jan 2013
- 340 KB
Publication Part Number | 5991-1834EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|---|
Russian (Russia) | Complete (PDF) |
必威体育登录手机An Agilent 7890B Series GC equipped with a new high temperature FPD was used to determine the sulfur compound distribution of benzothiophenes in heavier fuels and feedstocks
- Publication Part Number: 5991-1752EN
- Created: 28 Jan 2013
- 537 KB
Publication Part Number | 5991-1752EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机An Agilent 7890B Series GC equipped with a mid-column backflush configuration is described for the analysis of benzene and toluene in finished gasoline.
- Publication Part Number: 5991-1852EN
- Created: 28 Jan 2013
- 1 MB
Publication Part Number | 5991-1852EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A method has been developed on the Agilent 5977A Series GC/MSD for the detection of 16 PAHs at levels as low as 5 parts per billion (ppb)
- Publication Part Number: 5991-1811EN
- Created: 21 Jan 2013
- 173 KB
Publication Part Number | 5991-1811EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
必威体育登录手机최저 5ppb 수준, SVOC 30종 검출을 위해 Agilent 5977A 시리즈 GC/MSD로 개발한 분석법은 뛰어난 직선성 및 재현성을 가집니다.
- Publication Part Number: 5991-2127KO
- Created: 05 Mar 2019
- 2 MB
Publication Part Number | 5991-2127EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
帶 7697A 頂空進樣器的安捷倫氣質聯用血液酒精濃度分析儀能夠滿足毒理學家快速、準確和精確地測量血液中乙醇含量的需求。
- Publication Part Number: 5991-4059CHCN
- Created: 19 May 2014
- 4 MB
Publication Part Number | 5991-4059EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
雙柱/雙 FID 的配置組合在測定複雜血液基質中的酒精時能夠提供良好的精度和重現性。
- Publication Part Number: 5991-3671CHCN
- Created: 25 Nov 2013
- 487 KB
Publication Part Number | 5991-3671EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent 5977A GC/MSD を用いたウィスキーの香気成分のケモメトリクスプロファイリング
- Publication Part Number: 5991-2547JAJP
- Created: 08 Aug 2013
- 1 MB
Publication Part Number | 5991-2547EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|