Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Detection Technique
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 7000 Triple Quadrupole GC/MS (3)
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Separation of 30 polychlorinated biphenyls and pesticides is achieved by gas chromatography with highly apolar Agilent J&W CP-Sil 5/C18 for PCB in 46 minutes.
- Publication Part Number: A01506
- Created: 31 Oct 2011
- 688 KB
Publication Part Number | A01506 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 15 chlorinated pesticides in 15 minutes.
- Publication Part Number: A0360
- Created: 31 Oct 2011
- 942 KB
Publication Part Number | A00360 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates ten chloro- and sulfur pesticides and polychlorinated biphenyls in 18 minutes.
- Publication Part Number: A00597
- Created: 31 Oct 2011
- 643 KB
Publication Part Number | A00597 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W VF-Xms column separates 16 chlorinated pesticides in under ten minutes.
- Publication Part Number: A01990
- Created: 31 Oct 2011
- 605 KB
Publication Part Number | A01990 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 27 chloropesticides and polychlorinated biphenyls in 22 minutes.
- Publication Part Number: A00596
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A00596 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|