Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 30 non-volatile organic acids (BSTFA derivatives) in 28 minutes.
- Publication Part Number: A0254
- Created: 18 May 2015
- 1 MB
Publication Part Number | A00254 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Application note for Agilent Hi-Plex Columns for the Analysis of Organic Acids in Dairy Products
- Publication Part Number: SI-01159
- Created: 11 Feb 2014
- 1 MB
Publication Part Number | SI-01159 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Application note for Agilent Hi-Plex Columns for Carbohydrates, Alcohols, and Acids
- Publication Part Number: 5990-8264EN
- Created: 11 Feb 2014
- 220 KB
Publication Part Number | 5990-8264EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
The Hi-Plex H ligand-exchange chromatography column is able to separate mixture of mono-, di-, and trisaccharides, of alcoholic beverages during HPLC.
- Publication Part Number: SI-01676
- Created: 27 Sep 2012
- 160 KB
Publication Part Number | SI-01676 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
The Hi-Plex H ligand-exchange chromatography column and refractive index (RI) detector can quantify levels of sugars, sugar alcohols, and organic acids in a mixture.
- Publication Part Number: SI-01675
- Created: 27 Sep 2012
- 152 KB
Publication Part Number | SI-01675 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 37 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01420
- Created: 31 Oct 2011
- 873 KB
Publication Part Number | A01420 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 31 organic acids and sucrose in roasted coffee (TMS derivatives) in 32 minutes.
- Publication Part Number: A00512
- Created: 31 Oct 2011
- 758 KB
Publication Part Number | A00512 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Application note for Agilent Hi-Plex Columns for Sugar Separation: Effects of Temperature and Mobile Phase
- Publication Part Number: SI-01153
- Created: 27 June 2011
- 277 KB
Publication Part Number | SI-01153 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for organic acids in silage
- Publication Part Number: SI-1945
- Created: 23 June 2011
- 290 KB
Publication Part Number | SI-01945 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for Agilent Hi-Plex Columns for Superior Resolution of Organic Acids in Wine
- Publication Part Number: SI-01152
- Created: 22 June 2011
- 405 KB
Publication Part Number | SI-01152 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for Agilent Hi-Plex Columns for Fingerprinting Organic Acids in Wine
- Publication Part Number: SI-01151
- Created: 22 June 2011
- 486 KB
Publication Part Number | SI-01151 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Acids can be analyzed on thick-film non-polar phases such as Agilent J&W CP-Sil 5 CB, though lactic acid and derivatives can overload rapidly, deforming peak shape.
- Publication Part Number: A02436
- Created: 11 May 2010
- 453 KB
Publication Part Number | A02436 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|