Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
-
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine components in a sample of medium-heat milk powder with an oxidation flavor.
- Publication Part Number: A0846
- Created: 31 Oct 2011
- 472 KB
Publication Part Number | A00846 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine components from a one-year-old Gouda cheese.
- Publication Part Number: A0847
- Created: 31 Oct 2011
- 709 KB
Publication Part Number | A00847 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates a test mix of 22 volatile organic compounds in water in 25 minutes.
- Publication Part Number: A1021
- Created: 31 Oct 2011
- 701 KB
Publication Part Number | A01021 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates seven C1 to C5 acetates in five minutes.
- Publication Part Number: A00007
- Created: 31 Oct 2011
- 321 KB
Publication Part Number | A00007 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column produces a fingerprint of apple juice aroma in 30 minutes.
- Publication Part Number: A0851
- Created: 31 Oct 2011
- 818 KB
Publication Part Number | A00851 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 18 flavors in apple juice with TCT (Trap Tenax TA) injection in 30 minutes.
- Publication Part Number: A0623
- Created: 31 Oct 2011
- 802 KB
Publication Part Number | A00623 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 11 components in a sample of yoghurt.
- Publication Part Number: A0845
- Created: 31 Oct 2011
- 481 KB
Publication Part Number | A00845 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a 0.15 mm id Agilent J&W CP-Sil 5 CB column separates residual solvents in less than seven minutes.
- Publication Part Number: A01502
- Created: 31 Oct 2011
- 788 KB
Publication Part Number | A01502 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten solvents in seven minutes.
- Publication Part Number: A0353
- Created: 31 Oct 2011
- 788 KB
Publication Part Number | A00353 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 19 solvents in 30 minutes.
- Publication Part Number: A0718
- Created: 31 Oct 2011
- 862 KB
Publication Part Number | A00718 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Application note for the analysis of Volatile Solvents on CP-Sil 5 CB using the Agilent 490 Micro GC
- Publication Part Number: 5990-8699EN
- Created: 25 July 2011
- 254 KB
Publication Part Number | 5990-8699EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|