Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
- Compounds
-
- Language
-
Language
Applied Filters
必威体育登录手机as chromatography using an Agilent J&W CP-Sil 5 CB column separates six solvents in sewage water in 15 minutes.
- Publication Part Number: A0705
- Created: 31 Oct 2011
- 601 KB
Publication Part Number | A00705 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Boiling point analysis of sulfur compounds in hydrogenated naphtha by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01812
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01812 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Boiling point analysis of sulfur compounds in kerosene (jet fuel) by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01813
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01813 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Boiling point analysis of sulfur compounds in cracked gasoil by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01811
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01811 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|