Application note for Volatile Organic Compounds in Serum or Plasma
- Publication Part Number: SI-2162
- Created: 29 Jan 2014
- 104 KB
Publication Part Number | SI-02162 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 52 CB column separates 27 C1 to C7 oxygenated compounds in a hydrocarbon matrix in 32 minutes.
- Publication Part Number: A01616
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01616 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 10 components in a sample of a beefsteak plant (Perilla sp.) in 40 minutes.
- Publication Part Number: A1031
- Created: 31 Oct 2011
- 589 KB
Publication Part Number | A01031 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of Japanese bean paste, miso, in 45 minutes.
- Publication Part Number: A1032
- Created: 31 Oct 2011
- 574 KB
Publication Part Number | A01032 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates four tricyclic antidepressants in ten minutes.
- Publication Part Number: A0159
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00159 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机An Agilent J&W CP-Wax 52 CB column separates 22 solvents by gas chromatography in 40 minutes.
- Publication Part Number: A01952
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01952 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a shampoo fingerprint in 45 minutes.
- Publication Part Number: A1040
- Created: 31 Oct 2011
- 747 KB
Publication Part Number | A01040 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates acrolein and acrylonitrile according to EPA 603 in ten minutes.
- Publication Part Number: A0782
- Created: 31 Oct 2011
- 375 KB
Publication Part Number | A00782 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of black sesame in 50 minutes.
- Publication Part Number: A1033
- Created: 31 Oct 2011
- 641 KB
Publication Part Number | A01033 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column determines an acetone impurity in Forane (isoflurane) in 11 minutes.
- Publication Part Number: A0766
- Created: 31 Oct 2011
- 411 KB
Publication Part Number | A00766 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 31 C6 to C13 polycyclic aromatic hydrocarbons in 51 minutes.
- Publication Part Number: A0652
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00652 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of parged sesame in 50 minutes.
- Publication Part Number: A1034
- Created: 31 Oct 2011
- 501 KB
Publication Part Number | A01034 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates five C5 to C7 cyclic alcohols in eight minutes.
- Publication Part Number: A0177
- Created: 31 Oct 2011
- 480 KB
Publication Part Number | A00177 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight glycols in 12 minutes.
- Publication Part Number: A0181
- Created: 31 Oct 2011
- 516 KB
Publication Part Number | A00181 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates ten C4 to C8 volatile alcohols in eight minutes.
- Publication Part Number: A0175
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00175 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 16 solvents in 21minutes.
- Publication Part Number: A00502
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00502 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates six C1 to C7 volatile alcohols in eight minutes.
- Publication Part Number: A0173
- Created: 31 Oct 2011
- 501 KB
Publication Part Number | A00173 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 23 C10 to C18 fatty acid methyl esters in ox fat in 28 minutes.
- Publication Part Number: A0474
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A00474 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column produces a fingerprint of shrimp aroma in 25 minutes.
- Publication Part Number: A0853
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A00853 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC separation of ten glycols using an Agilent J&W CP-Wax 52 CB column with FID is achieved in under 40 minutes.
- Publication Part Number: A01954
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01954 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|