必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates nine alcohols, acetates, aldehydes and dioxane in a whisky in 12 minutes.
- Publication Part Number: A0368
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00368 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates four C3 to C6 volatile alcohols in six minutes.
- Publication Part Number: A0174
- Created: 31 Oct 2011
- 425 KB
Publication Part Number | A00174 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 105 components in an apricot purée.
- Publication Part Number: A1023
- Created: 31 Oct 2011
- 3 MB
Publication Part Number | A01023 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 10 components in two Pilsener beers in 27 minutes.
- Publication Part Number: A1026
- Created: 31 Oct 2011
- 544 KB
Publication Part Number | A01026 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 16 alcohols and esters in a sample of Chateau Ventenac 1988 red wine in 45 minutes.
- Publication Part Number: A0469
- Created: 31 Oct 2011
- 783 KB
Publication Part Number | A00469 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight alcohols in red wine in 16 minutes.
- Publication Part Number: A0706
- Created: 31 Oct 2011
- 521 KB
Publication Part Number | A00706 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 52 CB column identifies dimethylsulfide in a sample of beer in 15 minutes.
- Publication Part Number: A00006
- Created: 31 Oct 2011
- 449 KB
Publication Part Number | A00006 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|