Application note for the determination of Volatile Amines using a CP-Volamine GC Column
- Publication Part Number: SI-01613
- Created: 29 Jan 2014
- 564 KB
Publication Part Number | SI-01613 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent J&W CP-Volamine provides a high degree of inertness for symmetrical elution of highly polar AEEA (2-aminoethyl ethanolamine).
- Publication Part Number: A01584
- Created: 31 Oct 2011
- 678 KB
Publication Part Number | A01584 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Volamine column separates impurities in trimethylamine in 18 minutes.
- Publication Part Number: A01585
- Created: 31 Oct 2011
- 371 KB
Publication Part Number | A01585 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Volamine column separates impurities in dimethylamine in nine minutes.
- Publication Part Number: A01564
- Created: 31 Oct 2011
- 361 KB
Publication Part Number | A01564 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Volamine column elutes volatile amines as symmetrical peaks, as well as low levels of alcohols, air and water.
- Publication Part Number: A01586
- Created: 31 Oct 2011
- 679 KB
Publication Part Number | A01586 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Highly inert Agilent J&W CP-Volamine analyzes polar impurities in amine streams!excellent separation of methanol and ethanol and sharp peaks for water and ammonia.
- Publication Part Number: A01994
- Created: 31 Oct 2011
- 509 KB
Publication Part Number | A01994 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent J&W CP-Volamine shows excellent elution of water and monomethylamine (MMA) at 40.8%.Titration was 41.2%, and so the GC method was of equivalent sensitivity.
- Publication Part Number: A01993
- Created: 31 Oct 2011
- 426 KB
Publication Part Number | A01993 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Impurities in monoethylene glycol are detected by GC/MS with an Agilent J&W CP-Volamine column in six minutes.
- Publication Part Number: A01917
- Created: 01 Oct 2011
- 680 KB
Publication Part Number | A01917 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Volamine column separates volatile sulfur compounds in eight minutes.
- Publication Part Number: A01865
- Created: 01 Oct 2011
- 717 KB
Publication Part Number | A01865 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of three glycols in water using an Agilent J&W CP-Volamine column is achieved in 18 minutes.
- Publication Part Number: A01854
- Created: 01 Oct 2011
- 771 KB
Publication Part Number | A01854 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Volamine column separates VOCs in less than four minutes.
- Publication Part Number: A01913
- Created: 01 Oct 2011
- 698 KB
Publication Part Number | A01913 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of glycolaldehyde in monoethylene glycol using an Agilent J&W CP-Volamine column takes seven minutes.
- Publication Part Number: A01859
- Created: 01 Oct 2011
- 743 KB
Publication Part Number | A01859 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Oxygenated compounds are separated by GC/MS on the amine-deactivated Agilent J&W CP-Volamine capillary column in 13 minutes.
- Publication Part Number: A01916
- Created: 01 Oct 2011
- 990 KB
Publication Part Number | A01916 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of six chlorinated phenols using an Agilent J&W CP-Volamine column is achieved in 30 minutes.
- Publication Part Number: A01855
- Created: 01 Oct 2011
- 829 KB
Publication Part Number | A01855 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Volamine column separates polar volatiles such as carbon dioxide, ammonia and water in under two minutes.
- Publication Part Number: A01915
- Created: 01 Oct 2011
- 735 KB
Publication Part Number | A01915 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
MMEA and MDEA are used to remove sulfur compounds from hydrocarbons.必威体育登录手机Agilent J&W CP-Volamine is ideal for these highly polar compounds.
- Publication Part Number: A01914
- Created: 01 Oct 2011
- 792 KB
Publication Part Number | A01914 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|