Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
A highly sensitive and specific 2-minute method for the quantitation of Cyclosporin A, Everolimus, Sirolimus, and Tacrolimus in whole blood.
- Publication Part Number: 5991-3344EN
- Created: 24 Sep 2015
- 994 KB
Publication Part Number | 5991-3344EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Due to the emerging and dangerous popularity of synthetic cathinones – compounds
- Publication Part Number: 5991-0180EN
- Created: 07 Aug 2014
- 1 MB
Publication Part Number | 5991-0180EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Using StreamSelect System for high throughput Vitamin D2 and D3 analysis
- Publication Part Number: 5991-2900EN
- Created: 21 July 2014
- 690 KB
Publication Part Number | 5991-2900EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A single sample prep method prior to LC/MS/MS and GC/MS used Agilent Bond Elut Certify to extract phencyclidine (PCP) from urine.
- Publication Part Number: 5991-4575EN
- Created: 09 May 2014
- 290 KB
Publication Part Number | 5991-4575EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
A method for determination of three azaspiracids in shellfish has been developed based on QQQ6460 LCMS platform with high sensitivity and accuracy.
- Publication Part Number: 5991-3336EN
- Created: 18 Mar 2014
- 288 KB
Publication Part Number | 5991-3336EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Method for Determination of Veterinary Drugs in Milk Using QuEChERS and LC-MS/MS
- Publication Part Number: 5991-3948EN
- Created: 06 Feb 2014
- 250 KB
Publication Part Number | 5991-3948EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
RapidFire/MS/MS is capable of analyzing clozapine and norclozapine in serum at
- Publication Part Number: 5991-3766EN
- Created: 20 Dec 2013
- 606 KB
Publication Part Number | 5991-3766EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
QuEChERS AOAC sample prep extracted 12 pesticide residues from various classes in chicken using LC/ESI/MS/MS, with mean recoveries from 76 to 107%, with RSD below 10%.
- Publication Part Number: 5991-3191EN
- Created: 11 Dec 2013
- 207 KB
Publication Part Number | 5991-3191EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent Bond Elut Plexa SPE combined with LC/MS/MS enables sensitive quantitation of hormones in meat samples at low ppb concentrations
- Publication Part Number: 5991-3660EN
- Created: 21 Nov 2013
- 227 KB
Publication Part Number | 5991-3660EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Macrolide residues were analyzed using Agilent Bond Elut Plexa SPE and Poroshell 120, with LC/Tandem MS.Recoveries were 67.8 to 106.6%, RSDs were 1.9 to 10.7%.
- Publication Part Number: 5991-3190EN
- Created: 12 Sep 2013
- 276 KB
Publication Part Number | 5991-3190EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|