Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Detection Technique
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Describing the use of the AOAC buffered extraction method followed by the use of the Universal Dispersive SPE method for preparing lettuce and apple samples for GC/MS.
- Publication Part Number: 5990-6558EN
- Created: 06 Jan 2012
- 961 KB
Publication Part Number | 5990-6558EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Fast GC analysis of 25 pesticides using splitless injection on a 0.15 mm id Agilent J&W CP-Sil 13 CB column.
- Publication Part Number: A02239
- Created: 31 Oct 2011
- 633 KB
Publication Part Number | A02239 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Application note for organophosphorus residues in Olive Oil by GC/FPD with Agilent J&W DB-35ms Ultra Inert
- Publication Part Number: 5990-7722EN
- Created: 21 Apr 2011
- 1 MB
Publication Part Number | 5990-7722EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Fast analysis of pesticides in an apple matrix is achieved by gas chromatography with an Agilent J&W CP-Sil 13 CB column and splitless injection.
- Publication Part Number: A02382
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02382 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast analysis of 23 pesticides is straightforward by gas chromatography with an Agilent J&W CP-Sil 13 CB column and splitless injection.
- Publication Part Number: A02381
- Created: 11 May 2010
- 575 KB
Publication Part Number | A02381 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|