Refine Results
- 必威体育赛事投注
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Detection Technique
- Injection Technique
- Instrument
-
必威体育登录手机Agilent 7683 Automatic Liquid sampler (2)
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
A modified Bond Elut QuEChERS method was validated for the extraction of 27 pesticide residues from a high lipid olive matrix prior to GC/MS/MS.
- Publication Part Number: 5991-4800EN
- Created: 18 June 2014
- 316 KB
Publication Part Number | 5991-4800EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Application note for the analysis of Pesticide Residues in Spinach Using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4305EN
- Created: 06 Jan 2012
- 1,000 KB
Publication Part Number | 5990-4305EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Describing the use of the AOAC buffered extraction method followed by the use of the Universal Dispersive SPE method for preparing lettuce and apple samples for GC/MS.
- Publication Part Number: 5990-6558EN
- Created: 06 Jan 2012
- 961 KB
Publication Part Number | 5990-6558EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
必威体育登录手机Application note for a Blind Study of Pesticides in Vegetables by Bond Elut QuEChERS Extraction Kits and Agilent 5975T LTM GC/MSD
- Publication Part Number: 5990-6323EN
- Created: 06 Jan 2012
- 121 KB
Publication Part Number | 5990-6323EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Application note for Organophosphorus Pesticides in Apple Matrix by GC/MS/FPD using an Agilent J&W DB-35ms Ultra Inert GC Column
- Publication Part Number: 5990-7165EN
- Created: 06 Jan 2012
- 841 KB
Publication Part Number | 5990-7165EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Chinese (Simplified) (United States) | Complete (PDF) |
---|
必威体育登录手机Application note for organophosphorus residues in Olive Oil by GC/FPD with Agilent J&W DB-35ms Ultra Inert
- Publication Part Number: 5990-7722EN
- Created: 21 Apr 2011
- 1 MB
Publication Part Number | 5990-7722EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Fast analysis of pesticides in an apple matrix is achieved by gas chromatography with an Agilent J&W CP-Sil 13 CB column and splitless injection.
- Publication Part Number: A02382
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02382 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|