An optimized extraction and clean-up method for fusarium toxin-contaminated cereals and cereal-based foods using Bond Elut Mycotoxin extraction sorbent is described.
- Publication Part Number: SI-00295
- Created: 22 Mar 2017
- 127 KB
Publication Part Number | SI-00295 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
This Application Note describes the TAG profile analysis of olive oil after solid phase extraction (SPE) according the Commission Regulation (EEC) No 2472/97.
- Publication Part Number: 5991-4709EN
- Created: 01 May 2016
- 570 KB
Publication Part Number | 5991-4709EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Analysis of chlorophyll degradation products in olive oil samples using the Agilent 1260 Infinity LC
- Publication Part Number: 5991-1896EN
- Created: 01 May 2016
- 727 KB
Publication Part Number | 5991-1896EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The fast and reproducible sample preparation capability of Agilent Captiva ND Lipids plates is shown in an analysis of plant polyphenols.
- Publication Part Number: 5991-1999EN
- Created: 15 Aug 2015
- 167 KB
Publication Part Number | 5991-1999EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
A modified Bond Elut QuEChERS method was validated for the extraction of 27 pesticide residues from a high lipid olive matrix prior to GC/MS/MS.
- Publication Part Number: 5991-4800EN
- Created: 18 June 2014
- 316 KB
Publication Part Number | 5991-4800EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Detection of multi-residue pesticides by Agilent 6495 QQQ MS in food matrices
- Publication Part Number: 5991-4687EN
- Created: 12 June 2014
- 477 KB
Publication Part Number | 5991-4687EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|---|
Russian (Russia) | Complete (PDF) |
An analytical method that is well established for the 7000 Series Triple Quadrupole GC/MS has been employed to demonstrate performance of the 7000C Triple Quadrupole GC/MS.
- Publication Part Number: 5991-4131EN
- Created: 21 Mar 2014
- 180 KB
Publication Part Number | 5991-4131EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
A method for determination of three azaspiracids in shellfish has been developed based on QQQ6460 LCMS platform with high sensitivity and accuracy.
- Publication Part Number: 5991-3336EN
- Created: 18 Mar 2014
- 288 KB
Publication Part Number | 5991-3336EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Method for Determination of Veterinary Drugs in Milk Using QuEChERS and LC-MS/MS
- Publication Part Number: 5991-3948EN
- Created: 06 Feb 2014
- 250 KB
Publication Part Number | 5991-3948EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Two sample preparation techniques were explored for the analysis of adulterants in erectile dysfunction dietary supplements using LC/MS/MS.
- Publication Part Number: 5991-3638EN
- Created: 03 Feb 2014
- 241 KB
Publication Part Number | 5991-3638EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent Captiva Premium regenerated-cellulose syringe filters are excellent for beverage additive analysis, with excellent recovery and particulate removal efficiency.
- Publication Part Number: 5991-3737EN
- Created: 12 Dec 2013
- 465 KB
Publication Part Number | 5991-3737EN | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||||
Instrument |
|
|||||||||
Analytical Technique | Technique |
|
||||||||
Injection |
|
|||||||||
Detection |
|
|||||||||
Sample | Chemical Group |
|
||||||||
示例矩陣 |
|
QuEChERS AOAC sample prep extracted 12 pesticide residues from various classes in chicken using LC/ESI/MS/MS, with mean recoveries from 76 to 107%, with RSD below 10%.
- Publication Part Number: 5991-3191EN
- Created: 11 Dec 2013
- 207 KB
Publication Part Number | 5991-3191EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent Bond Elut QuEChERS kits provided adequate cleanup, recovery, and reproducibility of 176 pesticides in highly pigmented tea samples.
- Publication Part Number: 5991-3728EN
- Created: 09 Dec 2013
- 190 KB
Publication Part Number | 5991-3728EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent Bond Elut Plexa SPE combined with LC/MS/MS enables sensitive quantitation of hormones in meat samples at low ppb concentrations
- Publication Part Number: 5991-3660EN
- Created: 21 Nov 2013
- 227 KB
Publication Part Number | 5991-3660EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Esters of 3-monochloropropane-1,2-diol (3-MCPD) are contaminants formed in several
- Publication Part Number: 5991-3406EN
- Created: 31 Oct 2013
- 558 KB
Publication Part Number | 5991-3406EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Method development for QuEChERS sample preparation is used to extract pesticide residues in highly variable concentrated fruit juices, followed by GC/MS/MS
- Publication Part Number: 5991-3342EN
- Created: 21 Oct 2013
- 6 MB
Publication Part Number | 5991-3342EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
An online SPE LCMS method has been developed for the rapid and robust analysis of trace organic compounds in water, eliminating the need for tedious extractions.
- Publication Part Number: 5991-2731EN
- Created: 08 Oct 2013
- 1 MB
Publication Part Number | 5991-2731EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机This Application Note describes a robust method for the determination of glyphosate and AMPA using the Agilent 1200 Infinity Series Online SPE Solution.
- Publication Part Number: 5991-3208EN
- Created: 01 Oct 2013
- 818 KB
Publication Part Number | 5991-3208EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The Agilent Inert Flow Path outperformed a non-Agilent version for trace pesticides, with less impact on analytes and better results for some critical pesticides.
- Publication Part Number: 5991-3234EN
- Created: 19 Sep 2013
- 925 KB
Publication Part Number | 5991-3234EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Macrolide residues were analyzed using Agilent Bond Elut Plexa SPE and Poroshell 120, with LC/Tandem MS.Recoveries were 67.8 to 106.6%, RSDs were 1.9 to 10.7%.
- Publication Part Number: 5991-3190EN
- Created: 12 Sep 2013
- 276 KB
Publication Part Number | 5991-3190EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|