Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Four-channel Agilent 490 Micro GC analyzes refinery gas, permanent gases, hydrogen sulfide, and all saturated and unsaturated hydrocarbons up to C5, in 150 s.
- Publication Part Number: A01786
- Created: 31 Oct 2011
- 810 KB
Publication Part Number | A01786 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in a chlor-alkali cell in 60 seconds.
- Publication Part Number: A02064
- Created: 31 Oct 2011
- 729 KB
Publication Part Number | A02064 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in 25 seconds.
- Publication Part Number: A02065
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A02065 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates acetylene, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0892
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A00892 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-AL2O3/KCl column module and Agilent 490 Micro GC separates 14 C1 to C4 hydrocarbons in 200 seconds.
- Publication Part Number: A0906
- Created: 31 Oct 2011
- 675 KB
Publication Part Number | A00906 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four gases in air in 22 seconds.
- Publication Part Number: A00887
- Created: 31 Oct 2011
- 530 KB
Publication Part Number | A00887 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
Publication Part Number | 5990-9165EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|