Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using a custom-made Agilent J&W CP-Sil 88 column separates six sugars as their hexa-acetates in four minutes.
- Publication Part Number: A0168
- Created: 31 Oct 2011
- 609 KB
Publication Part Number | A00168 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five sugars as hexa-acetates in 25 minutes.
- Publication Part Number: A00084
- Created: 31 Oct 2011
- 590 KB
Publication Part Number | A00084 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten sugars as their TMS derivatives in 60 seconds.
- Publication Part Number: A0708
- Created: 31 Oct 2011
- 578 KB
Publication Part Number | A00708 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W VF-23ms column separates nine alditol acetates in four minutes.
- Publication Part Number: A01969
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A01969 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates trisilylimidazole/BSTFA sugar derivatives in hexane in 30 minutes.
- Publication Part Number: A01328
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A01328 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W VF-23ms column separates eight alditol acetates in nine minutes.
- Publication Part Number: A01968
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A01968 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|