Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Method
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 12 C5 to C8 alcohols in 25 minutes.
- Publication Part Number: A01107
- Created: 31 Oct 2011
- 317 KB
Publication Part Number | A01107 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 C10 to C16 alkanes in 15 minutes.
- Publication Part Number: A00087
- Created: 31 Oct 2011
- 659 KB
Publication Part Number | A00087 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of mineral oil in soil or water is achieved in eight minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C10 to C40.
- Publication Part Number: A02016
- Created: 31 Oct 2011
- 587 KB
Publication Part Number | A02016 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 11 C4 to C8 alcohols in 36 minutes.
- Publication Part Number: A01106
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A01106 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with Agilent J&W CP-Sil 5 CB Low Bleed/MS separates 14 components in a sample of mineral oil in 35 minutes, according to the Dutch standard NVN 6678.
- Publication Part Number: A01322
- Created: 31 Oct 2011
- 787 KB
Publication Part Number | A01322 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates 16 C8 to C40 hydrocarbons in 12 minutes.
- Publication Part Number: A0998
- Created: 31 Oct 2011
- 604 KB
Publication Part Number | A00998 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机An oncolumn method is used for soil analysis by GC, allowing C10 to C40 to be determined in less than 5 minutes with Agilent J&W Select Mineral Oil.
- Publication Part Number: A01976
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A01976 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机With Agilent J&W VF-5ht, on-column injection of diesel minimizes discrimination effects that can occur in split, splitless and PTV type injection systems.
- Publication Part Number: A02367
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02367 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|