Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Language
-
Language
Applied Filters
Application note for the GC analysis of 37 FAME Component Mixture using CP-Select for FAME Column
- Publication Part Number: SI-2164
- Created: 30 Jan 2014
- 169 KB
Publication Part Number | SI-02164 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of eight FAMEs in butter is achieved in less than five minutes, using the Agilent J&W VF-23ms GC column.
- Publication Part Number: A01972
- Created: 31 Oct 2011
- 903 KB
Publication Part Number | A01972 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机By using an Agilent J&W VF-23ms GC column seven FAMES from sunflower oil can be separated in seven minutes.
- Publication Part Number: A01974
- Created: 31 Oct 2011
- 769 KB
Publication Part Number | A01974 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The low bleed Agilent J&W VF-23ms delivers fast GC separation of FAME isomers from olive oil within five minutes.
- Publication Part Number: A01975
- Created: 31 Oct 2011
- 649 KB
Publication Part Number | A01975 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of 23 FAMEs in fish oil is achieved in 15 minutes, using the Agilent J&W VF-23ms GC column.
- Publication Part Number: A01971
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01971 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with a 200-m Agilent J&W CP-Select CB for FAME column individually quantifies 15 trans fatty acids in 54 minutes, with high separation efficiency.
- Publication Part Number: A01892
- Created: 01 Oct 2011
- 906 KB
Publication Part Number | A01892 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select CB for Fame column separates 19 fatty acid methyl esters in under 60 minutes.
- Publication Part Number: A01911
- Created: 01 Oct 2011
- 769 KB
Publication Part Number | A01911 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select CB for Fame column separates 14 C18:1 cis/trans FAME isomers in milk fat in 52 minutes.
- Publication Part Number: A01909
- Created: 01 Oct 2011
- 2 MB
Publication Part Number | A01909 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of fatty acids in Infant Formulas Using a J&W HP-88 Capillary GC Column
- Publication Part Number: 5990-8429EN
- Created: 17 June 2011
- 426 KB
Publication Part Number | 5990-8429EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|