Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
A highly sensitive and reliable method has been developed for 51 nonpolar compounds in potable water, and PBDEs, PAHs, and diazinon in wastewater.
- Publication Part Number: 5991-1553EN
- Created: 16 Jan 2013
- 1 MB
Publication Part Number | 5991-1553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 60 pesticides and polycyclic biphenyls in 24 minutes.
- Publication Part Number: A0709
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00709 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 23 pesticides and polychlorinated biphenyls in a standard mixture in 26 minutes.
- Publication Part Number: A0478
- Created: 31 Oct 2011
- 699 KB
Publication Part Number | A00478 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates ten chloro- and sulfur pesticides and polychlorinated biphenyls in 18 minutes.
- Publication Part Number: A00597
- Created: 31 Oct 2011
- 643 KB
Publication Part Number | A00597 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 27 chloropesticides and polychlorinated biphenyls in 22 minutes.
- Publication Part Number: A00596
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A00596 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Separation of 30 polychlorinated biphenyls and pesticides is achieved by gas chromatography with highly apolar Agilent J&W CP-Sil 5/C18 for PCB in 46 minutes.
- Publication Part Number: A01506
- Created: 31 Oct 2011
- 688 KB
Publication Part Number | A01506 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|