Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Language
-
Language
Applied Filters
必威体育登录手机Analysis of sulfur and oxygenated compounds on an Agilent J&W Lowox column in 29 minutes.
- Publication Part Number: A02073
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02073 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten C1 to C6 volatile alcohols in 1-hexanol in 15 minutes.
- Publication Part Number: A0162
- Created: 31 Oct 2011
- 860 KB
Publication Part Number | A00162 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates four impurities in ethanol in 19 minutes.
- Publication Part Number: A0689
- Created: 31 Oct 2011
- 570 KB
Publication Part Number | A00689 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column separates oxygenates in a C1 to C6 hydrocarbon matrix in 23 minutes.
- Publication Part Number: A01362
- Created: 31 Oct 2011
- 887 KB
Publication Part Number | A01362 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC separation of 37 oxygenated compounds on a highly selective Agilent J&W Lowox multilayer column is achieved in 45 minutes.
- Publication Part Number: A02251
- Created: 31 Oct 2011
- 874 KB
Publication Part Number | A02251 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01424 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|