Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Detection Technique
- Injection Technique
- Instrument
-
必威体育登录手机Agilent 7000 Triple Quadrupole GC/MS (4)
必威体育登录手机Agilent 7683 Automatic Liquid sampler (2)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
A modified Bond Elut QuEChERS method was validated for the extraction of 27 pesticide residues from a high lipid olive matrix prior to GC/MS/MS.
- Publication Part Number: 5991-4800EN
- Created: 18 June 2014
- 316 KB
Publication Part Number | 5991-4800EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Effective analysis of multiple pesticides in water used an Agilent 5975T LTM GC/MSD with stir bar sorptive extraction and a Thermal Separation Probe.
- Publication Part Number: 5991-4264EN
- Created: 14 Mar 2014
- 230 KB
Publication Part Number | 5991-4264EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for GC Analysis of Halogenated Pesticides using the Agilent J&W FactorFour VF-1701ms with EZ-Guard
- Publication Part Number: SI-02247
- Created: 29 Jan 2014
- 150 KB
Publication Part Number | SI-02247 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Method development for QuEChERS sample preparation is used to extract pesticide residues in highly variable concentrated fruit juices, followed by GC/MS/MS
- Publication Part Number: 5991-3342EN
- Created: 21 Oct 2013
- 6 MB
Publication Part Number | 5991-3342EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
A highly sensitive and reliable method has been developed for 51 nonpolar compounds in potable water, and PBDEs, PAHs, and diazinon in wastewater.
- Publication Part Number: 5991-1553EN
- Created: 16 Jan 2013
- 1 MB
Publication Part Number | 5991-1553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
A GC/MS/MS method for the analysis of pesticide residues in fruits and vegetables was developed, optimized, and successfully implemented
- Publication Part Number: 5991-1054EN
- Created: 11 Oct 2012
- 641 KB
Publication Part Number | 5991-1054EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
A novel sample preparation regime has been developed for the extraction and cleanup
- Publication Part Number: 5990-9865EN
- Created: 20 Aug 2012
- 2 MB
Publication Part Number | 5990-9865EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Compared to other vendor's columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
Publication Part Number | 5991-0615EN | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
示例矩陣 |
|
必威体育登录手机Agilent J&W DB-CLP1 and DB-CLP2 columns separated organohalides from water, while enabling reliable detection at and below EU and EPA maximum contaminant levels.
- Publication Part Number: 5991-0207EN
- Created: 29 Mar 2012
- 922 KB
Publication Part Number | 5991-0207EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for sub μg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/μECD
- Publication Part Number: 5990-9735EN
- Created: 20 Jan 2012
- 1 MB
Publication Part Number | 5990-9735EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
Chinese (Simplified) (China) | Complete (PDF) |
Describing the use of the AOAC buffered extraction method followed by the use of the Universal Dispersive SPE method for preparing lettuce and apple samples for GC/MS.
- Publication Part Number: 5990-6558EN
- Created: 06 Jan 2012
- 961 KB
Publication Part Number | 5990-6558EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Application note for the determination of pesticides in lemon oil via modified QuEChERS method
- Publication Part Number: 5990-6432EN
- Created: 06 Jan 2012
- 1 MB
Publication Part Number | 5990-6432EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
必威体育登录手机Application note for a Blind Study of Pesticides in Vegetables by Bond Elut QuEChERS Extraction Kits and Agilent 5975T LTM GC/MSD
- Publication Part Number: 5990-6323EN
- Created: 06 Jan 2012
- 121 KB
Publication Part Number | 5990-6323EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (United States) | Complete (PDF) |
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for PCBs column separates 12 chlorinated pesticides according to EPA 505 in 23 minutes.
- Publication Part Number: A0778
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00778 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 27 chloropesticides and polychlorinated biphenyls in 22 minutes.
- Publication Part Number: A00596
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A00596 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 15 chlorinated pesticides in 15 minutes.
- Publication Part Number: A0360
- Created: 31 Oct 2011
- 942 KB
Publication Part Number | A00360 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 60 pesticides and polycyclic biphenyls in 24 minutes.
- Publication Part Number: A0709
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00709 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates 21organochlorine pesticides in 40 minutes.
- Publication Part Number: A00055
- Created: 31 Oct 2011
- 780 KB
Publication Part Number | A00055 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 23 pesticides and polychlorinated biphenyls in a standard mixture in 26 minutes.
- Publication Part Number: A0478
- Created: 31 Oct 2011
- 699 KB
Publication Part Number | A00478 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 29 pesticides according to EPA 508 in 64 minutes.
- Publication Part Number: A0780
- Created: 31 Oct 2011
- 551 KB
Publication Part Number | A00780 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|