Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 7683B Automatic Liquid sampler (1)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Application note for GC Analysis of Basic and Neutral Compounds on Agilent J&W FactorFour VF-35ms with EZ-Guard
- Publication Part Number: SI-02248
- Created: 30 Jan 2014
- 145 KB
Publication Part Number | SI-02248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Following the European Standard EN 71 part 11, an economical solution for the determination of VOCs was developed on a 7820A GC with a 5977E GC/MSD Sys configured to a 7667A
- Publication Part Number: 5991-3604EN
- Created: 15 Nov 2013
- 133 KB
Publication Part Number | 5991-3604EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Analysis of multiple semi-volatile organic compounds by USEPA method 8270D is challenging.It was performed by GC/MS with FactorFour VF-5ms column and quadrupole MS, giving 7
- Publication Part Number: SI-2365
- Created: 01 Aug 2013
- 253 KB
Publication Part Number | SI-02365 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
Publication Part Number | 5991-2153EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A 29-component subset mix of basic, neutral, and acidic compounds was used to evaluate the Agilent J&W DB-UI 8270D Ultra Inert GC column, compared to a non-Agilent column
- Publication Part Number: 5991-1505EN
- Created: 15 Nov 2012
- 875 KB
Publication Part Number | 5991-1505EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Extending J&W Factor Four VF-17ms Column with EZ-Guard with out leakage.
- Publication Part Number: SI-02222
- Created: 27 Sep 2012
- 118 KB
Publication Part Number | SI-02222 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
DB-UI 8270D 0.18 mm id (with Ultra Inert liners) and 0.25 mm id columns provided excellent peak shapes and performance for semi-volatile water pollutants.
- Publication Part Number: 5991-0250EN
- Created: 24 Aug 2012
- 770 KB
Publication Part Number | 5991-0250EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 35 solvents in 12 minutes.
- Publication Part Number: A0185
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00185 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 14base neutrals in 20 minutes.
- Publication Part Number: A02089
- Created: 31 Oct 2011
- 484 KB
Publication Part Number | A02089 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 15 C3 to C10 ketones in ten minutes.
- Publication Part Number: A0178
- Created: 31 Oct 2011
- 637 KB
Publication Part Number | A00178 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Nitro aromatics and cyclic ketones are analyzed by GC according to EPA 8090 using the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- Publication Part Number: A02285
- Created: 31 Oct 2011
- 700 KB
Publication Part Number | A02285 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC/MS analysis of eight nitroaromatics and cyclic ketones according to EPA 8090, with an Agilent J&W VF-200ms column, is achieved in less than 20 minutes.
- Publication Part Number: A02097
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A02097 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC separation of 13 nitro and sulfur compounds according to EPA 8270 is achieved in 20 minutes with an J&W Agilent VF-17ms column.
- Publication Part Number: A02279
- Created: 31 Oct 2011
- 965 KB
Publication Part Number | A02279 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates nine nitroaromatics and cyclic ketones according to EPA 8090 in 33 minutes.
- Publication Part Number: A0800
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A00800 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00789 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机For GC separation of 14 nitrosamines in under 20 minutes use the stabilized 50% phenyl PDMS phase of an Agilent J&W VF-17ms column.
- Publication Part Number: A02276
- Created: 31 Oct 2011
- 761 KB
Publication Part Number | A02276 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 33 solvents and other organics in 13 minutes.
- Publication Part Number: A0128
- Created: 31 Oct 2011
- 767 KB
Publication Part Number | A00128 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 15 C3 to C9 ketones in 10 minutes.
- Publication Part Number: A00014
- Created: 31 Oct 2011
- 464 KB
Publication Part Number | A00014 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A00805 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with direct injection of nitro and halogenated aromatic compounds (base neutrals) is accomplished by the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- Publication Part Number: A02295
- Created: 31 Oct 2011
- 753 KB
Publication Part Number | A02295 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|