Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Detection Technique
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 7000 Triple Quadrupole GC/MS (4)
必威体育登录手机Agilent 7683B Automatic Liquid sampler (2)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
An analytical method that is well established for the 7000 Series Triple Quadrupole GC/MS has been employed to demonstrate performance of the 7000C Triple Quadrupole GC/MS.
- Publication Part Number: 5991-4131EN
- Created: 21 Mar 2014
- 180 KB
Publication Part Number | 5991-4131EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Effective analysis of multiple pesticides in water used an Agilent 5975T LTM GC/MSD with stir bar sorptive extraction and a Thermal Separation Probe.
- Publication Part Number: 5991-4264EN
- Created: 14 Mar 2014
- 230 KB
Publication Part Number | 5991-4264EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Substituting the VF-1701 Pesticides column can be used in place of the Restek Rtx-CLPesticides1 column and the VF-5 Pesticides column.
- Publication Part Number: SI-00924
- Created: 03 Feb 2014
- 177 KB
Publication Part Number | SI-00924 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
English (United States) | Complete (PDF) |
---|
必威体育登录手机Application note for GC Analysis of Halogenated Pesticides using the Agilent J&W FactorFour VF-1701ms with EZ-Guard
- Publication Part Number: SI-02247
- Created: 29 Jan 2014
- 150 KB
Publication Part Number | SI-02247 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Flow path inertness is critical in pesticide analysis for accuracy and precision
- Publication Part Number: 5991-1862EN
- Created: 21 Mar 2013
- 779 KB
Publication Part Number | 5991-1862EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
A highly sensitive and reliable method has been developed for 51 nonpolar compounds in potable water, and PBDEs, PAHs, and diazinon in wastewater.
- Publication Part Number: 5991-1553EN
- Created: 16 Jan 2013
- 1 MB
Publication Part Number | 5991-1553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
A GC/MS/MS method for the analysis of pesticide residues in fruits and vegetables was developed, optimized, and successfully implemented
- Publication Part Number: 5991-1054EN
- Created: 11 Oct 2012
- 641 KB
Publication Part Number | 5991-1054EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Agilent Ultra Inert liners with wool give accurate and precise pesticide trace levels from 5 µL extracts in acetonitrile.
- Publication Part Number: 5991-1196EN
- Created: 04 Oct 2012
- 1 MB
Publication Part Number | 5991-1196EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
A novel sample preparation regime has been developed for the extraction and cleanup
- Publication Part Number: 5990-9865EN
- Created: 20 Aug 2012
- 2 MB
Publication Part Number | 5990-9865EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent J&W DB-CLP1 and DB-CLP2 column pair performs rapid, high-resolution separations of CLP pesticides, US EPA methods, and similar semi-volatile mixtures
- Publication Part Number: 5991-0541EN
- Created: 06 Aug 2012
- 482 KB
Publication Part Number | 5991-0541EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Compared to other vendor's columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
Publication Part Number | 5991-0615EN | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
示例矩陣 |
|
必威体育登录手机Agilent J&W DB-CLP1 and DB-CLP2 columns separated organohalides from water, while enabling reliable detection at and below EU and EPA maximum contaminant levels.
- Publication Part Number: 5991-0207EN
- Created: 29 Mar 2012
- 922 KB
Publication Part Number | 5991-0207EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for sub μg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/μECD
- Publication Part Number: 5990-9735EN
- Created: 20 Jan 2012
- 1 MB
Publication Part Number | 5990-9735EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
Chinese (Simplified) (China) | Complete (PDF) |
Application note for GC-μECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil
- Publication Part Number: 5990-5553EN
- Created: 06 Jan 2012
- 1 MB
Publication Part Number | 5990-5553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 15 organochlorine pesticides in 39 minutes.
- Publication Part Number: A1092
- Created: 31 Oct 2011
- 672 KB
Publication Part Number | A01092 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an AgilentJ&W CP-Sil 19 CB column separates 30 organochlorine pesticides in 59 minutes.
- Publication Part Number: A1094
- Created: 31 Oct 2011
- 679 KB
Publication Part Number | A01094 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of 16 organochlorine pesticides according to EPA 625 is achieved in less than 23 minutes using Agilent J&W VF-5ms EZ-Guard columns.
- Publication Part Number: A02208
- Created: 31 Oct 2011
- 886 KB
Publication Part Number | A02208 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for PCBs column separates 12 chlorinated pesticides according to EPA 505 in 23 minutes.
- Publication Part Number: A0778
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00778 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 29 pesticides according to EPA 508 in 64 minutes.
- Publication Part Number: A0780
- Created: 31 Oct 2011
- 551 KB
Publication Part Number | A00780 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 22 pesticides in 18 minutes.
- Publication Part Number: A01251
- Created: 31 Oct 2011
- 762 KB
Publication Part Number | A01251 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|