Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Detection Technique
-
- Injection Technique
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates oxygen, nitrogen, methane and carbon monoxide in coke gas in 55 seconds.
- Publication Part Number: A0869
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00869 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column analyzes eight decomposition gases from the explosive, 1,3,3-trinitroazetidine in 25 minutes.
- Publication Part Number: A01440
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A01440 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separate oxygen, argon, carbon monoxide, hydrogen, nitrogen, and methane in helium in 95 s.
- Publication Part Number: A0862
- Created: 31 Oct 2011
- 330 KB
Publication Part Number | A00862 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates gases in a water sample in 10 minutes.
- Publication Part Number: A0992
- Created: 31 Oct 2011
- 535 KB
Publication Part Number | A00992 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates four gases in two minutes.
- Publication Part Number: A0291
- Created: 31 Oct 2011
- 416 KB
Publication Part Number | A00291 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Four-channel Agilent 490 Micro GC analyzes refinery gas, permanent gases, hydrogen sulfide, and all saturated and unsaturated hydrocarbons up to C5, in 150 s.
- Publication Part Number: A01786
- Created: 31 Oct 2011
- 810 KB
Publication Part Number | A01786 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-COx column module and Agilent 490 Micro GC analyzes carbon monoxide and carbon dioxide in 250 seconds.
- Publication Part Number: A0990
- Created: 31 Oct 2011
- 487 KB
Publication Part Number | A00990 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column elutes sulfur gases without interference from light hydrocarbons, in ten minutes.
- Publication Part Number: A01292
- Created: 31 Oct 2011
- 791 KB
Publication Part Number | A01292 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates four gases in five minutes.
- Publication Part Number: A0683
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00683 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates five permanent gases in less than three minutes.
- Publication Part Number: A01246
- Created: 31 Oct 2011
- 434 KB
Publication Part Number | A01246 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates helium, oxygen, nitrogen, methane, hydrogen, and carbon monoxide in 70 s.
- Publication Part Number: A0870
- Created: 31 Oct 2011
- 352 KB
Publication Part Number | A00870 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with Agilent J&W CP-Molsieve separates permanent gas contaminants in beverage-grade CO2 in ten minutes.
- Publication Part Number: A01645
- Created: 31 Oct 2011
- 348 KB
Publication Part Number | A01645 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates oxygen, nitrogen, carbon monoxide and other gases in air in four minutes.
- Publication Part Number: A0495
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A00495 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight gases and volatiles in 13 minutes.
- Publication Part Number: A01610
- Created: 31 Oct 2011
- 409 KB
Publication Part Number | A01610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Agilent 490 Micro GC with an Agilent J&W CP-Molsieve 5Å analyzes air near a garbage dump for neon, hydrogen, oxygen, nitrogen, methane and carbon monoxide in 240 s.
- Publication Part Number: A01619
- Created: 31 Oct 2011
- 417 KB
Publication Part Number | A01619 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column analyzes carbon dioxide and carbon monoxide in hydrocarbon streams in six minutes.
- Publication Part Number: A01431
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A01431 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separate oxygen, nitrogen, methane, carbon dioxide, and hydrogen in 30 seconds.
- Publication Part Number: A0855
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A00855 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in four minutes.
- Publication Part Number: A0294
- Created: 31 Oct 2011
- 372 KB
Publication Part Number | A00294 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC detects low ppm levels of oxygen, nitrogen, methane and carbon monoxide in 39 s.
- Publication Part Number: A0868
- Created: 31 Oct 2011
- 357 KB
Publication Part Number | A00868 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|